I N S T A L L A T I O N I N S T R U C T I O N S
© 2012 Quam-Nichols Company Quam-Nichols reserves the right to make changes and/or improvements to its products at any time and without notice.
12– 2.20
8 0 8 8
4. Feed supply cable through whip to connector.
Make connections per wiring diagrams below;
Insulate all unused taps from each other, the enclosure
and electrical
ground.
When cover plate is secured, all connections / splices and
unused leads must be inside of the enclosure.
5. Place assembly onto ceiling grid,
install 24” T-bar
trim piece where required (furnished only with specific
1’x2’ formats).
NOTE! AHJ/ local codes may require tie-off to structure.
Bend up tie-off tabs as shown in illustration and install as
directed.
NOTE! AHJ/ local codes may require tie-down to grid.
Recommended fasteners;
not supplied
: Erico/Caddy part
ATA4i and 1/4”-20 x 2” bolt, or equivalent. Install as
directed.
6. Place remaining ceiling tile
into opening as required.
BLACK ( Common )
BLACK ( Common )
8Ω
8Ω
QUAM /25RS and /70RS Rotary Select
QUAM /25RS and /70RS Rotary Select
4W
4W
0.25W
0.25W
0.5W
0.5W
1W
1W
2W
2W
OFF
OFF
RED
RED
INTENDED USE:
All versions: Indoor environment, mounted parallel to floor
plane in a 24” wide, suspended ceiling tile grid; mount height
18’ or less above floor plane.
Program material: Signal tones, voice and music.
1. Cut ceiling tile as required:
1’ x 2’ FORMAT
LOUDSPEAKER
2’ x 2’ tile – Cut tile in half along one axis.
2’ x 4’ tile – Cut 12” from edge along 2’ axis and
discard smaller piece.
2’ x 2’ FORMAT
LOUDSPEAKER
2’ x 2’ tile – No cutting required.
2’ x 4’ tile – Cut tile in half along 2’ axis.
!
Steps 2-3 –
Required only if using conduit clamp
fitting
other than what is provided
with product.
2. Loosen, but do not remove screws
on cover plate;
push up and remove plate from assembly.
3. Remove cable /conduit clamp fitting from plate
;
Install UL Listed metallic enclosure entry fitting for
plenum cable or flex whip.
Tie-off
tab 2x
Tie-off
tab 4x
Brown 5W @ 25V
only
Red
2.5W @ 25V
only
Violet
only
0.32W @ 70.7V
Gray
only
0.63W @ 70.7V
Blue
only
1.25W @ 70.7V
White 0.32W @ 25V
or
2.5W @ 70.7V
Green 0.63W @ 25V
or
5W @ 70.7V
Orange 1.25W @ 25V
only
BLACK ( Common )
8Ω
8Ω
QUAM Model TBLU
BLACK ( Common )
BLACK ( Common )
8Ω
8Ω
QUAM 8-Ohm Operation
QUAM 8-Ohm Operation
RED
RED
Blue 10W
White 5W
Yellow 0.63W
Red 1.25W
Green 2.5W
BLACK ( Common )
8Ω
8Ω
QUAM Model TCH70