background image

8

Step 2: Carefully lift the insert into the 
mantle opening. The front of the INSERT 
should be flush with the front of the mantle.

Step 3: Once the INSERT is in place, attach 
3 MOUNTING CLIPS (R) on the top of the 
INSERT and lock the insert in place with 3 
SHORT KD SCREWS (X). See fig. L

 

fig. L

Step 4: Attach 2 MOUNTING BRACKET (W) to 
the bottom with 2 KD SCREWS. See fig. L

Step 5: Move assembled unit to desired 
location. Unit should not be positioned in 
area exposed to direct sunlight.

WALL ANCHOR 

SAFETY CABLE

The use of WALL ANCHOR SAFETY CABLE 
is highly recommended in order to reduce 
the risk of the fireplace being tipped over 
accidentally. WARNING: This CABLE may 
reduce possible risk of injury if the fireplace 
is improperly handled, but is not a substi-
tute for proper adult supervision. Children 
should not be left unattended near any 
heater.
 
1. Drill a 5/16 in (8 mm) hole in the wall. 
Insert the PLASTIC WALL ANCHOR into the 

hole and gently tap until the flange on the 
anchor is against the wall surface.

2. Position the back edge of the mantle close 
to the wall.

3. Attach the SAFETY CABLE to the mantle 
using the SCREW FOR MANTLE.  See figure 
M or N.

4. Use the SCREW FOR WALL to attach the 
other end of SAFETY CABLE to the wall.

5. Make sure all screws are tight.

A S S E M B LY   I N S T R U C T I O N S

fig. M

fig. N

Summary of Contents for M650-38A-OAK

Page 1: ...I N S T R U C T I O N M A N U A L M650 38A OAK NDF 65NB 1 ATTENTION 1 Find a location for the fireplace heater that is protected from direct sunlight 2 Do not plug the unit into the power outlet before you read all instructions ...

Page 2: ...cause product damage or personal injury 1 Read all instructions before using this electric fireplace heater 2 This electric fireplace heater is hot when in use To avoid burns do not let bare skin touch hot surfaces The grill directly in front of the heater outlet becomes hot during heater operation Keep combustible materi als such as furniture pillows bedding papers clothes and curtains at least 3...

Page 3: ...AWG minimum size and rated not S A F E T Y I N S T R U C T I O N S less than 1875 watts The extension cord shall be a 3 wire cord with a grounding type cord and plug connector 16 Do not plug this product into a receptacle controlled by a wall switch or dimmer 17 When storing or transporting the unit and cord keep in a dry place free from excessive vibration and store so as to avoid damage CAUTION ...

Page 4: ...red to operate this heater If the breaker trips when the heater is used then you may need to move the heater to another location or un plug other appliances that are on the same circuit If you require an extension cord use one that is rated at 1875 watts SAVE THESE INSTRUCTIONS FOR FUTURE USE S A F E T Y I N S T R U C T I O N S ...

Page 5: ... up repair paint bottle L shape bracket 8 Screws for L shape 32 Plastic connector 1 KD screws 3 KD nuts 3 W Mounting bracket 2 X Short KD screws 3 fig A TOOL REQUIRED PHILLIPS HEAD SCREWDRIVER MANTLE ASSEMBLY CAUTION Place a piece of cardboard or protective sheet on the floor in order to avoid scratching the decorative surface of your mantle during assembly Please DO NOT fully tighten the KD screw...

Page 6: ...he RIGHT FRONT PANEL G with 3 KD SCREWS See fig C Step 4 Attach the LEFT K F H and RIGHT L G J SIDE PANELS to the BASE PANEL B using 4 KD SCREWS 2 screws on each side See Fig D Step 5 Place the LOWER FRONT PANEL E in between the lower sections of LEFT RIGHT SMALL PANEL H and J and attach with 2 KD SCREWS 1 screw each side See Fig E Step 6 Place the UPPER FRONT PANEL D in between the upper section ...

Page 7: ... Fig I Step 10 Install the TOP PANEL A to the unit as shown with 4 KD SCREWS See Fig J Step 11 Tighten all SCREWS Fig K FIREPLACE INSERT INSTALLATION The fireplace insert can be installed after the mantle has been fully assembled WARNING Make sure the fireplace insert controls are in the OFF position and the unit is NOT plugged in Step 1 Place the INSERT on the floor di rectly in front of the MANT...

Page 8: ...ommended in order to reduce the risk of the fireplace being tipped over accidentally WARNING This CABLE may reduce possible risk of injury if the fireplace is improperly handled but is not a substi tute for proper adult supervision Children should not be left unattended near any heater 1 Drill a 5 16 in 8 mm hole in the wall Insert the PLASTIC WALL ANCHOR into the hole and gently tap until the fla...

Page 9: ...h while the ON OFF switch is in the on position for low heat The indicator light will turn on 1500W For high heat function Press this switch while the ON OFF switch and the 750W switch are in the on position for high heat The indicator light will turn on Temperature Control To adjust the tempera ture to your individual requirements turn the temperature control dial to the right clock wise to incre...

Page 10: ...ntal burning of the skin RISK OF FIRE DO NOT EXCEED THE RECOMMENDED BULB WATTAGE M A I N T E N A N C E REPLACING THE LIGHT BULBS Step 1 Remove 4 screws on the back of fireplace and remove the rear cover of the unit Step 2 You will find 2 X E12 40W Type B 10 bulbs under log set bed Step 3 Loosen and remove burnt out bulb s and replace with new bulb s Step 4 Close the rear cover and secure with the ...

Page 11: ...s and gloves if necessary WARNING Wear goggles before you start drilling Option 1 Use the spare KD NUTS KD SCREWS and PLASTIC CONNECTOR 1 Place the PLASTIC CONNECTOR on the mantel unit and mark the drill holes as shown in Fig B fig B 2 Drill the holes with diameter 3 4 inches 10 mm and depth 3 4 inches 10mm on the mantel Each Plastic Connector needs 3 holes See Fig C fig C fig D 3 Gently install t...

Page 12: ...aners or spray liquids on glass display panel surface Metal and metal painted parts should be cleaned with damp cloth Do not use abrasive cleaners or spray liquids on these surfaces WARRANTY Every electric fireplace heater is tested before it leaves the factory and it is guaranteed for one year If the unit should fail to operate correctly within one year from the date of purchase call customer ser...

Page 13: ...bulbs are not covered by this warranty The warranty is for homeowner use only and does not cover units used in commercial situations Imported by Quality Craft Laval Quebec Canada H7S 2G7 1 800 459 4409 EST www qualitycraft com Made in China ...

Reviews: