background image

X-RAY RADIATION PRECAUTION

 

1.

 

Excessive high voltage can produce potentially hazardous X-Ray Radiation.' To avoid such hazards,
the high voltage must not be above the specified limit. The normal value of the high voltage of this
receiver is 24KV at zero beam current (minimum brightness) under 220V AC power source. The high
voltage must not, under any circumstances, exceed 30KV.

 

2.

 

Each time a receiver requires servicing, the high voltage should be checked following the High
Voltage Check procedure in this manual. It is recommended the reading of the high voltage be
recorded as a part of the service record, it is important to use an accurate and reliable high voltage
meter.

 

3.

 

The primary source of X-Ray Radiation in this TV Receiver is the picture tube. For continued X-Ray
Radiation protection, the replacement tube must be exactly the same type tube as specified in the
part list.

 

4.

 

Some parts in this receiver have special safety - related characteristics for X-Ray Radiation
protection. For continued safety, parts replacement should be undertaken only after referring to the
Product Safety Notice.

SAFETY PRECAUTION

Warning: Service should not be attempted by anyone unfamiliar with necessary precaution on this receiver.
The following are the necessary precautions observed before servicing this chassis.

 

1.

 

Since the power supply circuit of this receiver is directly connected to the AC power line, an
isolation transformer should be used during any dynamic service to avoid possible shock hazard.

 

2.

 

Always discharge the picture tube anode to the CRT conductive coating before handling the picture
tube. The picture tube is highly evacuated and if broken, glass fragment will be violently expelled.
Use shatter proof goggles and keep picture tube away from the unprotected body while handling.

 

3.

 

When replacing a chassis in the cabinet, always be certain that all the protective devices are put
back in place, such as: non-metallic control knobs, insulating covers, shields, isolation resistor-
capacitor network etc.

 

4.

 

When replacing parts or circuit boards, disconnect the power cord.

 

5.

 

When replacing a high wattage resistor (Metal oxide film resistor) on circuit board, keep the
resistor 10mm (1/2in.) away from circuit board.

 

6.

 

Connection wires must be kept away from components with high voltage or high temperature.

 

7.

 

If any fuse in this TV receiver is blown, replace it with the FUSE specified in the chassis part list.

 

8.

 

The receiver is designed to operate with 220V(50/60Hz) AC mains.

PRODUCT SAFETY NOTICE

Many electrical and mechanical parts in this chassis have special safety-related characteristics. These
characteristics are often passed unnoticed by a visual inspection and the X-Ray Radiation protection
afforded by them cannot necessarily be obtained by using replacement components rated for high wattage,
etc. Replaced parts which have these special safety characteristics are identified in this manual and its
supplements, electrical components having such features are shaded on the schematic diagram and the part
list.
Before replacing any of these components, read the part list in this manual carefully. The use of substitute
replacement parts, which do not have the same safety characteristics, as specified in the part list may create
shock, fire, and X-Ray Radiation or other hazards.

Summary of Contents for CTV-37V10

Page 1: ...G DK Models 14 CTV 37V10 chasis 3401 21 CTV 55V10 chasis 4401 C C C CA A A AU U U UT T T TI I I IO O O ON N N N Before serving the chassis read the X Ray Radiation Precaution Safety Precaution and Pro...

Page 2: ...e CRT conductive coating before handling the picture tube The picture tube is highly evacuated and if broken glass fragment will be violently expelled Use shatter proof goggles and keep picture tube a...

Page 3: ...justment 2 1 small screwdriver 2 2 screwdriver without inductance 2 3 Pattern Generator 2 4 DC Regulated power supply 2 5 Digital Voltmeter 2 6 Sweep Signal Generator 2 7 20MHz 2 channel Oscilloscope...

Page 4: ...1 of IC302 and negative terminal of D608 DC Regulated power supply negative terminal connects to pin 2 of IC302 1 3 Adjust L203 coil to obtain 3 6V Digital voltage meter reading 2 System NTSC Adjust L...

Page 5: ...erminals 3 4 Adjust VR601 to obtain 110V 0 5V 4 AGC alignment 4 1 Receive 60dB 2dB RF signal Connect Digital voltmeter positive terminal to AGC terminal of TUNER and negative terminal to GND 4 2 Press...

Page 6: ...ght area 4 3 1 Go to factory mode MENU2 according to 4 4 2 Obtain Low Bright area to x 281and y 311 by adjusting R bias and B bias Obtain High Bright area to x 281and y 311 by adjusting R drive and B...

Page 7: ...ard the front of CRT and set it where a uniform green field is obtained Tighten the clamp screw of the deflection yoke 7 Restore the values of R BIAS G BIAS and B BIAS CONVERGENCE ADJUSTMENT 8 Receive...

Page 8: ......

Page 9: ...MENU 2 V KILL 0 R C 128 G C 180 B C 125 R D 48 G D 10 B D 63 COLLOR TEST 0 MENU 4 SUB_BRI 123 OSD CONT 100 B GAM SEL 0 RG GAM DEF 0 SCM B_Y DC 8 SCM R_Y DC 4 BLUE BLACK 1 C E OSD 0 OPTION 2 AV CH 0 C...