1.Loosen the screws and remove E
-
parts cover from the unit.
2.Connect the cables respectively to the corresponding terminals
of the terminal board of the outdoor unit (see the wiring diagram),
and if there are signals connected to the plug, just conduct butt joint.
3.Ground wire: Remove the grounding screw out of the electric
bracket, cover the grounding wire end onto the grounding screw
and screw it into the grounding hole.
4.Fix the cable reliably with fasteners (Pressing board).
5.Put the E
-
parts cover back in its original place and fasten
it with screws.
E parts cover
-
1
2
L
N
Wiring Connection
Wiring
diagram
Connector
If there is a connector,
connect it directly.
constant speed
Heat-pump type
Variable speed
Cooling Only
1
2(N)
1
2
3
To Indoor unit
To Indoor unit
1
2(N)
4
5
To Indoor unit
5
3
4
1
2
To Indoor unit
To Indoor unit
1(
L
) 2(N) 4(S)
NOTE:
※
This manual is usually includes the wiring mode for the different kind of A/C.
We cannot exclude the possibility that some special type of wiring diagrams
are not included.
※
The diagram are for reference only. If the entity is difference with this wiring
diagram, please refer to the detailed wiring diagram adhered on the unit which
you purchased.
Install outdoor unit
- 19 -