Quadra-Fire • Columbia Bay Insert • 7002-109 Rev. H • 10/08
16
C. Door Crown Installation
Open lower access panel. Pull out and unhook the two
spring latches on the bottom of the appliance that secure
the door.
Rotate the door forward approximately 1-1/2 in. (38 mm).
Holding the ashlip, lift the door up off of the stationary
latches and away from the appliance.
Note:
Use a soft cloth and a window cleaning solution to clean
all fi ngerprint oils from the gold or nickel surface of crown
PRIOR to lighting the appliance.
Figure 8.1
Figure 8.2
Figure 8.3
Figure 8.4
8
8
Appliance Setup
A. Remove Shipping Materials
Remove shipping materials from inside or underneath the
fi rebox.
B. Accessories
Install approved accessories per instructions included
with accessories. See Service Parts List for appropriate
accessories.
Shock or fi re risk.
Use ONLY optional accessories approved for
this appliance.
• Using non-listed accessories voids warranty.
• Using non-listed accessories may result in a
safety hazard.
• Only Hearth & Home Technologies approved
accessories may be used safely.
WARNING
STATIONARY LATCHES
STATIONARY LATCHES
SPRING LOADED LATCHES
SPRING LOADED LATCHES
Uninstall the existing crown by removing the four screws
on the back side of the door. Retain the screws.
Use a fl at-head screwdriver to pry the black crown free on
the right side. Remove the crown and discard.
Carefully align the left side of the crown into place, and
wrap it across the face of door, fi nally
snapping it into
place on the right hand side. Reinsert and tighten the
screws previously removed.