Model
Trekker Pellet Appliance
Laboratory
OMNI Test Laboratories, Inc.
Report No.
061-S-83-2
Type
Solid Fuel Room Appliance, Pellet Fuel
Burning Type
Standard
ASTM E1509-12, ULC S627-00 and
(UM) 84-HUD, Mobile Home Approved.
FCC
Complies with Part 15 of FCC Rules.
Operation is subject to the following two
conditions: (1) this device may not cause
harmful interference, and (2) this device
must accept any interference received,
including interference that may cause
undesired operation.
A. Appliance Certification
B. BTU & Efficiency Specifications
Emissions Report
Number:
0061PS094E
EPA Certification #:
98-17
EPA Certified Emissions:
0.74 g/hr
*LHV Tested Efficiency:
83.2%
**HHV Tested Efficiency:
77.9%
***EPA BTU Output:
12,682 - 39,428 / HR
****BTU Input:
16,396 - 50,775 / HR
Vent Size:
3, 4 or 6 inches, “L” or “PL”
Hopper Capacity:
52 lbs.
Fuel
Wood Pellets
* Weighted average LHV efficiency using data collected
during EPA emissions test.
**Weighted average HHV efficiency using data collected
during EPA emissions test.
***A range of BTU outputs based on HHV and the burn
rates from the low and high EPA tests.
****Maximum BTU input based on the high burn section
of the EPA emissions test.
This pellet appliance needs periodic inspection and repair for proper operation. It is against federal regulations to operate
this pellet appliance in a manner inconsistent with operating instructions in this manual.
NOTICE:
This installation must conform with local codes. In the absence of local codes you must comply with the
ASTM E1509-04, ULC S627-00, (UM) 84-HUD and ULC/ORD-C-1482.
This manual describes the installation of the Quadra-Fire, Trekker pellet appliance. This appliance meets the 2020 U.S.
Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2020. Under specific test
conditions this appliance has been shown to deliver heat at rates ranging from 12,682 to 39,428 Btu/hr.