d. Temperature Calibration
The TEMPERATURE CAL screen is used to calibrate the
temperature on the wall control. If for some reason you feel
the wall control is not accurately reading the temperature
you can calibrate it to a thermostat that you know is ac
-
curate. Press the UP/DOWN buttons to the desired tem
-
perature.
c. Temp Differential
The TEMPERATURE DIFFERENTIAL screen is used to
change the set default temperature differential. This sets
how far below the set point the wall control allows the room
temperature to fall before the appliance turns back on. It is
usually set at time of installation.
Figure 7.1
e. Properties
The PROPERTIES screen shows the version of software for
the control board and wall control. If you are placing a service
call with your dealer, they may ask you to go to this screen
and read them the information under “WC” and “SC”.
TEMPERATURE CAL
71.6
O
F Cal Adj:
-13
DONE
SET
WC
SC
CB
CV
40h
6Bh
000
000
UFTI: 029
Rev: 004
TC: -28
PROPERTIES
DONE
Figure 7.2
Figure 7.3
f. Elevation
The ELEVATION screen allows you to adjust the appliance
to your specific elevation. Press the UP/DOWN buttons
to select your elevation. The message in the center will
change between NORMAL and HIGH. If you select HIGH,
it will replace the normal fuel tables with specific high fuel
tables. You
MUST
select a fuel type after selecting HIGH.
Please note that changing the elevation will delete any
custom or new fuel table loaded into the appliance. You
must confirm your choice on the CONFIRM ELEVATION
CHANGE screen. This allows you to reverse your decision
if necessary.
Figure 7.5.
ELEVATION
Over 4000 FT
Normal / High
Up to 4000 FT
DONE
Figure 7.4
g. Convection Blower Speed
The CONV BLOWER SPEED screen allows you to ad
-
just the blower speed to your individual preference. Press
the UP/DOWN buttons to select your blower speed. The
message in the center will change between NORMAL and
QUIET.
NORMAL allows the convection blower to reach maximum
RPM at 135 degrees and QUIET at 165 degrees.
CONV BLOWER SPEED
Normal
Normal / Quiet
Quiet
DONE
Figure 7.6
CONFIRM ELEVATION CHANGE
YES
Changing elevations will
delete any custom or
new fuel tables loaded into
the stove.
Are you sure?
NO
Figure 7.5