D. Use of Elbows
diagonal runs have both vertical and horizontal vent aspects
when calculating the effects. Use the rise for the vertical
aspect and the run for the horizontal aspect. See Figure 4.4.
two 45º elbows may be used in place of one 90º elbow. on
45º runs, one foot of diagonal is equal to 8-1/2 in. (216 mm)
horizontal run and 8-1/2 in. (216 mm) vertical run. a length
of straight pipe is allowed between two 45º elbows. See
Figure 4.4.
Figure 4.5 shows the vertical and horizontal offsets for SlP
elbows.
Figure 4.4
HORIZONTAL
VERTICAL
RUN
RIS
E
EF
FE
CT
IVE
LE
NG
TH
Y
X
X
X
Vent Type
X
Inches
Millimeters
SlP
11-1/4
286
Figure 4.5 Vertical and Horizontal Offset for SLP Elbows
E. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards:
• Pipe measurements are shown using the effective length of
pipe. See Figure 11.1 for SlP for information on effective
length of pipe components.
• horizontal terminations are measured to the outside
mounting surface (flange of termination cap) (see Figure
4.3).
• Vertical terminations are measured to bottom of
termination cap.
• horizontal pipe installed level with 1/4 inch rise per foot.
Vent
Type
X
Y
Inches Millimeters Inches Millimeters
SlP
5
127
11-3/4
298
SLP
Pipe
Effective Length
Rise/Run
Inches
Millimeters
Inches
Millimeters
SlP4
4
102
2-3/4
70
SlP6
6
152
4-1/4
108
SlP12
12
305
8-1/2
216
SlP24
24
610
17
432
SlP36
36
914
25-1/2
648
SlP48
48
1219
34
864
SlP6a
3 to 6
76 to 152
2-1/8-4-1/4
54-108
SlP12a
3 to 12
76 to 305
2-1/8-8-1/2
54-216
Y
X
X