B. Clearances to Combustibles
when selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
3.2).
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be located
out of traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
NOTICE:
Some carpet materials may be sensitive to
radiant heat from the appliance causing discoloration or
odor.
Figure 3.2 Appliance Locations
Model
A
B
C
D
E
F
G
H
Top of
pipe
Side of
pipe
Inside Outside
corner wall
vent
SaPh-MBK-IPI
SaPh-d-PMh-IPI
SaPh-d-MBK-IPI
SaPh-d-CSB-IPI
Inches
8-1/2
1/4
3/8
54-5/8
36
39
27
3
1
9
Millimeters
216
6
10
1388
914
991
686
76
25
229
A
B
F
E
A
"A"
measurement is from
stove top, not side
G
H
D
C
C
A
G
A
C. Hearth Extension/Floor Protection
CAUTION! Risk of Fire or Injury!
Install appliance on a
stable, level, platform or floor strong enough to support
appliance without tipping.
a non-combustible hearth pad is not required. however,
the floor beneath the appliance must be stable, level, and
strong enough to support the appliance without a tipping
hazard. It is permissible to place the appliance on carpet.
NOTE:
Flooring beneath appliance may reach 90 degrees
plus room ambient temperature. Check with flooring
manufacturer for maximum temperature allowed on flooring
surfaces.
Note:
dimensions are minimums as shown and may not be typical for all applications. an alcove installation is
shown above on left.
Alcove Installation