QFP 30 Direct Vent Gas Fireplace
Page 10
03/21/01 #250-6120
1. Remove door/glass by releasing four spring clips (2
upper and 2 lower). See Pg. 32.
2. Remove logset, lava rock, embers and packaging
materials from firebox.
3. Familiarize yourself with this manual.
4. Finalize your installation decisions and require-
ments.
5. Convert to LP gas if applicable to your installation.
(Conversion kit is included with unit.) See
Pgs.11-12.
6. Set unit in place and install venting per your installation
requirements. (See venting instructions, page 16-27.)
Secure unit to floor using naildown plates.
7. Connect the gas line. See Pg. 29.
8. Complete electrical connections. See Pg. ___.
9. Run thermostat lines to TH & TPTH connectors on
valve, if applicable. See Pg. 29.
10. Leak test gas line to manual shutoff valve. See
Pg. 33.
11. Install brick, lava rock, embers and logset. See
Pg. 30-31.
12. Turn on manual shutoff valve (installed by installer);
leak test.
13. Light pilot with door off and smell for gas (see Lighting
Instructions). See Pg.34.
14. Re-attach door with latches. See Pg. 32.
15. Adjust gas control knob to “ON” (again, follow Lighting
Instructions).
16. Check flames. See Pg. 33.
17. Adjust damper position, if applicable. See Pg. 35.
18. Attach fascia. NOTE: If using Gold or Brushed
Nickel Fascia - Clean thoroughly with glass cleaner
and non-abrasive towel prior to lighting unit. See
Pg. 32.
19. Set Thermostat or turn control panel switch to the
“On” position. See Pg. 36.
PREP
ARA
TION
• Failure to follow all of the required installation
procedures may result in property damage, bodily
injury or loss of life.
• This appliance must be installed in accordance
with all local codes, if any; if not, follow ANSI
Z223.1-1992 and NFPA 54(88).
• Manufactured Home or Mobile Home installation
may occur only after the home is site located
and must conform to: USA, Manufactured Home
Construction and Safety Standard, Title 24 CFR,
Part 3280; Canada, CSA Z240.4 and Gas-Equipped
Recreational Vehicles and Mobile Housing stan-
dards.
• The QFP 30 is manufactured to operate on Natural
Gas (NG), it is convertible to Liquid Propane Gas
(LP) when the manufacturer’s conversion kit,
included with the fireplace, is used.
• All exhaust gases must be vented outside the
structure of the living-area. Combustion air is drawn
from outside the living-area structure.
• Notify your insurance company prior to connecting
gas to this fireplace.
• Installation requirements diagrammed and explained
in this manual are grouped into segments for ease of
procedure. While these requirements must be met
fully, the order of installation may be subject to the
procedure best suited for your specific placement
of the fireplace.
PREPARATION
AN OVERVIEW: INSTALLATION TO
OPERATION