Quadra-Fire • QFI30FB, QFI35FB • 2221-900 Rev. K • 3/11
J. Air Shutter Setting
Air shutter settings should be adjusted by a qualifi ed ser-
vice technician at the time of installation. The air shutter is
set at the factory for minimum vertical vent run. Adjust air
shutter for longer vertical runs. See Figure 12.3.
NOTICE: If sooting occurs, provide more air by opening
the air shutter.
Figure 12.3 Air Shutter
Figure 12.2 Fixed Glass Assembly
I. Fixed
Glass
Assembly
WARNING! Risk of Asphyxiation! Handle fi xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
•
DO NOT
strike, slam or scratch glass.
•
DO NOT
operate fi replace with glass removed, cracked,
broken or scratched.
•
Replace as a complete assembly.
Removing Fixed Glass Assembly
•
The glass assembly fastens to the fi replace in four
places. The fastening mechanisms are spring-loaded
glass latches. An example of the glass latch is
shown in Figure 12.2.
• To release glass assembly, pull the two top spring-
loaded latches forward and allow them to retract
away from the glass assembly. Slide the glass as-
sembly outward and downward until top of the glass
frame will clear the surround.
Replacing Fixed Glass Assembly
•
Tilt glass assembly toward fi replace and slide glass
assembly downward to engage bottom latches. Verify
bottom latches are fully engaged and then fasten the
two top latches.
•
Note that the extended glass latch tabs on the glass
frame are for the bottom glass latches.
Air Shutter Settings
NG
LP
QFI30FB
1/4 in.
Full Open
QFI35FB
1/4 in.
Full Open
GLASS
ASSEMBLY
LATCHES
(BOTH BOTTOM
AND TOP)
AIR SHUTTER