11
Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Owner’s Manual • 2555-981 Rev. B • 6/18
NOTICE:
Some functionality will be lost when using battery
backup including remote control, fan, lights, or any other
auxiliary functions that require household 110-120 VAC
power.
To Return to Operation Using Electrical (AC) Power
IFT-RC150 Wireless Wall Switch or Wireless Remote:
• Remove the batteries and uninstall the battery pack.
Replace door or decorative barrier front on appliance.
Ignition Module:
• Slide the ON/REMOTE/OFF switch to the REMOTE
position.
• Remove the batteries and uninstall the battery pack.
Replace door or decorative front on appliance.
Figure 3.3 Access to Control Cavity
Figure 3.4
Figure 3.5
HEARTH
BATTERY PACK
Figure 3.6
Removing Battery Wire Tray - Pulling the left side out first
will allow the tray to clear the notch on the right side edge.
To re-install the tray, do the reverse and install the notch
to the edge first.
With the appliance pulled out of the chimney, the removal
of the front screw will allow panel to rotate up. The mod-
ule can gently be removed from the cavity to adjust the
switch to the proper settings.
Battery Wire Tray is located to the left of the reset switch
and glass clip. Plug the battery Tray’s red wire to the red
wire, and black wire to black wire. Rotate connectors 180
degrees if plugging is difficult. Connectors will not plug
into the wrong connector.