Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16
18
Figure 5.2 Fireplace Opening
In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B).
MINIMUM FIREPLACE SIZE
Location
QFI35-C
QFI30-C
Inches
Millimeters
Inches
Millimeters
A
Rear Width
23-7/16
595
20-3/16
513
B
Front Width
34-5/8
879
30-5/8
778
C
Glass Opening Width
31-5/8
803
27-1/2
699
D
Glass Opening Height
15-11/16
398
12-3/16
310
E
Height-Front
24-1/16
611
20-7/16
519
F
Height-Rear
21-1/8
537
17-5/8
448
G**
Unit Depth
15-3/4
400
14-3/4
375
H
Venting Depth
10-5/8
270
9-1/2
241
I
Height to Top of
Glass Frame
21-5/8
549
18-1/4
464
* Note: If exhaust collar on insert and fireplace damper do not line up, add 4 inches (102 mm) to minimum
fireplace height for bends in vent pipe.
**Unit depth is measured to the back of the surround to give the depth needed for installation.
TOP VIEW
FRONT VIEW
SIDE VIEW
E
D
C
I
F
B
A
G
H