8
7082-131J
August 3, 2015
MT VERNON E2 INSERT
Fire Risk.
Comply with all minimum clearances to
combustibles as specifi ed.
Failure to comply may cause house
fi re.
WARNING
Note:
•
Illustrations
refl ect typical installations and
are FOR DESIGN PURPOSES ONLY.
•
I
llustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual
design preference.
C
A
B
A
B. Clearance To Combustibles, US & Canada
Location
Confi guration
Inches
Millimeters
A
Side of Outside Skin
Top or Rear Vent
2
51
B
Vent Pipe to Combustible
Top or Rear Vent
3
76
C
Cast Side to Side Wall
Top or Rear Vent
6
152
J
K
3 in
[76mm]
Outside
Air
3 in
[76mm]
6 in
[152mm]
3 in
[76mm]
Built-in Unit - Rear Vent with Outside Air
Figure 8.1
Figure 8.2
Built-in Unit - Rear Vent
Note: In Canada where passage through a
wall or partition of combustible construction is
desired, the installation shall conform to
CAN/CSA-B365.
Through the wall, horizontal termination cap
must be a minimum of 6” (152mm) from the
wall. Approved for mobile home installations.
Must use 3” or 4” (76-102mm) “L” or “PL”
listed pellet venting or listed double wall pipe
and a Quadrafi re outside air kit (OAK3) in
mobile homes.