8
7034-277B
May 2, 2014
MT. VERNON AE
Straight Back Against Wall
Inches
Millimeters
A
Back Wall to Appliance
2
51
B
Side Wall to Appliance
6
152
Corner Installation
Inches
Millimeters
C
Walls to Appliance
2
51
Vertical Installation
Inches
Millimeters
D
Back Wall to Flue Pipe
3
76
E
Side Wall to Appliance
6
152
F
Back Wall to Appliance
8
203
Installations with:
3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit
Corner Installation
Inches
Millimeters
G
Side Wall to Flue Pipe
3
76
Alcove Installation
Inches
Millimeters
Minimum Alcove Height
43
1092
Minimum Alcove Side Wall
6
152
Minimum Alcove Width
40
1016
Maximum Alcove Depth
36
914
D
E
F
A
B
*L Exception for Horizontal Installations:
USA INSTALLATIONS
: A non-combustible floor protec-
tion is recommended extending beneath the flue pipe when
installed with horizontal venting or under the Top Vent
Adapter with vertical installation.
CANADA INSTALLATIONS
: A non-combustible floor pro-
tection extending beneath the flue pipe is
required
with hor-
izontal venting or under the Top Vent Adapter with vertical
installation.
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
•
I
llustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual design
preference.
C
C
G
G
L*
K
K
M
Use a non-combustible floor protector, extending beneath
appliance and to the front, sides and rear as indicated. Mea-
sure front distance “M” from the surface of the glass door.
Hearth Pad Requirements
Inches
Millimeters
K
Sides
2
51
L*
Back
2
51
M
Front
6
152
B. Clearances to Combustibles (UL and ULC)
C. Hearth Pad Requirements (UL and ULC)
Fire Risk.
Comply with all minimum clearances to combustibles
as specified.
Failure to comply may cause house fire.
WARNING