MT VERNON-AE TROUBLE SHOOTING MANUAL
7020-057C
4-24-08
CONTROL BOARD
SRV7000-456 Rev C
CONTROL BOARD SPECS 7.5 CODE: (Rev 2 fuel tables)
FUEL
UFTI SS LOW SS MED MAX IGNITER TIME A/C CYCLE TIME SHUTDOWN TIME
CORN:
0 14 MIN 12 MIN
14 MIN
2.4 HRS*
10 MIN
UTILITY PELLET:
1
4 MIN 5 MIN
4 MIN
1.2 HRS*
10 MIN
SOFTWOOD:
2
4 MIN 5 MIN
4 MIN
3.2 HRS*
10 MIN
SUNFLOWER SEEDS: 3
4 MIN 5 MIN
4 MIN
2.4 HRS*
10 MIN
WHEAT:
4 10 MIN 10 MIN
10 MIN
1.8 HRS*
10 MIN
HARDWOOD PELLET: 5
4 MIN 5 MIN
4 MIN
2.1 HRS*
10 MIN
*NOTE: AUTOCLEAN CYCLES TIMES ARE ESTIMATED WHEN THE UNIT IS RUN AT THE “HIGH” OUTPUT SETTING.
UPDATES:
SRV7000-323
ECO 56401 --- CHANGED FROM
6.9 TO 6.10A CODE
. INSTALLED POWER STROKE CODE FOR AUTOCLEAN AND
CHANGED TO THE “QUIET” CONVECTION BLOWER CURVE. REV 2 FUEL TABLES ALSO INSTALLED. (1-11-07)
SRV7000-330
ECO 56476 -- RELEASED WITH THE
7.2 CODE
. HIGH ELEVATION FUEL TABLES INSTALLED. 2 CONVECTION
BLOWER SPEED OPTIONS INSTALLED, 135 & 165 DEGREES TO GET TO THE HIGH BLOWER SPEED & EXHAUST
BLOWER STAYS ON DURING THE AUTO-CLEAN CYCLE AND 20 MINUTES AFTER AUTO-CLEAN IS COMPLETED.
(8-2-07 // SN 0072232364 INSERT /// SN 0072279399 FS)
SRV7000-456
ECO 58315 -- RELEASED WITH THE
7.3 CODE
0$'(620(83'$7(6727+((852)8(/7$%/(67KH\FDQ
EHDFFHVVHGE\WXUQLQJWKHURWDU\VZLWFKWRSRVLWLRQ
REV B --- RELEASED WITH THE
7.4 CODE.
ADDRESSED PREVIOUS AUTO-CLEAN PROBLEMS. SN 00700200343
REV C --- RELEASED WITH THE
7.5 CODE
. ADDRESSED LOGIC PROBLEM WITH VAC SWITCH & AUGER JAM.
PAGE 7