background image

19

March 26, 2020

7039-802B

4.  Glass Cleaning

•  Frequency: 

As desired

•  By:

 Homeowner

CAUTION

• 

Do not use polishes with abrasives. It will scratch 

plated surfaces.

CAUTION

• 

Do not use polishes with abrasives. It will 

scratch surfaces.

5.  Cleaning Plated Surfaces

•  Frequency: 

Prior to first burn and then as desired

•  By:

 Homeowner

Clean all the fingerprints and oils from plated surfaces 

BEFORE 

firing the appliance for the first time. If not 

cleaned properly before lighting your first fire, the oils can 

cause permanent markings on the plating.

After the plating is cured, the oils will not affect the finish 

and little maintenance is required. Wipe clean as needed.

Clean glass with a non-abrasive glass cleaner. Abrasive 

cleaners may scratch and cause glass to crack. If the 

deposits on the glass are not very heavy, normal glass 

cleaners work well. Heavier deposits may be removed by 

using a damp cloth dipped in wood ashes or by using a 

commercially available oven cleaner.

After using an oven cleaner, it is advisable to remove any 

residue with a glass cleaner or soap and water. Oven 

cleaner left on during the next firing can permanently stain 

the glass and damage the finish on metal surfaces.

A portion of the combustion air entering the firebox is 

deflected down over the inside of the door glass. This 

air flow “washes” the glass, helping to keep smoke from 

adhering to its surface.

When operated at a low burn rate, less air will be flowing 

over the glass and the smokey, relatively cool condition of a 

low fire will cause the glass to become coated.

Operating the appliance with the Burn Rate Air Control and 

Start-Up Air Control all the way open for 30-45 minutes 

should remove the built up coating.

CAUTION

Handle glass assembly with care. Glass is breakable.

•  Avoid striking, scratching or slamming glass

• 

Avoid abrasive cleaners

•  Do not clean glass while it is hot

6.  Inspect Firebrick

•  Frequency: 

After each ash removal

•  By:

 Homeowner

Replace the firebrick if they become crumbly and/or if there 

is a 1/4 inch (6.35mm) gap between the bricks.

The firebox is lined with firebrick, which has exceptional 

insulating properties. Do not use a grate; simply build 

a fire on the firebox floor. Do not operate appliance 

without firebrick.

1.  After the coals have completely cooled, remove all old 

brick and ash from unit and vacuum firebox.

2. 

Remove new brick set from box and lay out to the 

diagram shown in the instructions that come with the 

brick set or refer to the diagram on the service parts list 

at the end of this manual.

3. 

Lay bottom bricks in unit.

4. 

Install rear bricks on the top of the bottom bricks. Slide 

top of bricks under clip on back of firebox wall and push 

bottom of bricks back.

5. 

Install side bricks. Slide top of brick under clips on side 

of firebox and push the bottom of the brick until it is 

flush with the side of the unit.

Summary of Contents for MILLENNIUM 2100 Series

Page 1: ...s appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials...

Page 2: ...8 in USA Fuel loading door 5 3 4 in 2 1 4 in 29 5 8 in minimum 39 in minimum CANADA 203mm 8 in 203mm 8 in 203mm 8 in 457mm 18 in 1245mm 49 in minimum 1006mm 39 5 8 in minimum Made in U S A of US and i...

Page 3: ...ion 7 C BTU Efficiency Specifications 7 D Glass Specifications 8 E Mobile Home Approved 8 F Sleeping Room 8 G California Prop65 8 2 Operating Instructions 9 A Over Firing Your Appliance 9 B Wood Selec...

Page 4: ...nction boxes wire harnesses transformers and lights excluding light bulbs X X Molded Refractory Panels Glass Liners X Vent Free Burners Vent Free Logs X X Castings Medallions and Baffles 6 years 3 yea...

Page 5: ...ot covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted for a six year period to the original purchaser at catalyst WARRA...

Page 6: ...DD KINDLING LIGHT THE PAPER ADD MORE WOOD REDUCE AIR CONTROLS Set to desired heat output LOW BURN RATE CONTROL Upper Right Corner AUTOMATIC COMBUSTION CONTROL ACC Middle right hand side LOW The applia...

Page 7: ...k BTU Hour Output 44 400 Vent Size 6 inches Firebox Size 1 48 cubic feet Recommended Log Length 16 inches Fuel Seasoned Cord Wood 20 moisture Weighted average LHV Low Heating Value efficiency using Do...

Page 8: ...t be maintained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm...

Page 9: ...h enough to evaporate the moisture which is present in all wood The wood will reach the boiling point of water 212 F and will not get any hotter until the water is evaporated This process takes heat f...

Page 10: ...next stage of burning the secondary stage is the period when the wood gives off flammable gases which burn above the fuel with bright flames During this stage of burning it is very important that the...

Page 11: ...e knob is located under the high position Figure 11 1 2 Maximize Heat with The ACC System To maximize heat output with the ACC timer System or also known as high burn push the ACC Air Control lever to...

Page 12: ...etting Burn Rate Air Control spring handle up to high position for 5 minutes Then activate the ACC timer system by pushing the knob all the way back toward the appliance to HI then pull forwards towar...

Page 13: ...e appliance NEVER light or rekindle fire with kerosene gasoline or charcoal lighter fluid the results can be fatal 6 Once the kindling is burning quickly add several full length logs 3 inches 76mm or...

Page 14: ...tion If you find the blower coming on and off at undesirable temperatures relocate the snap disc to another location in the designated zone on the back of the appliance Figure 14 1 There is a manual o...

Page 15: ...e furnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting sho...

Page 16: ...TACT YOUR DEALER for additional information regarding operation and troubleshooting Visit www quadrafire com to find a dealer L Frequently Asked Questions WARNING Fire Risk DO NOT BURN GARBAGE OR FLAM...

Page 17: ...four 4 cords of wood The chimney and chimney cap must be inspected for soot and creosote every two months during the burn season or more frequency if chimney exceeds or is under 14 16 ft 4 3m 4 8m me...

Page 18: ...y connector and chimney should be inspected once every 2 months during the heating season to determine if a creosote or soot buildup has occurred If creosote or soot has accumulated it should be remov...

Page 19: ...he glass helping to keep smoke from adhering to its surface When operated at a low burn rate less air will be flowing over the glass and the smokey relatively cool condition of a low fire will cause t...

Page 20: ...tact with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Baffle Retainer Bracket WARNING Fire Risk Firebox damage due to improper baffle pla...

Page 21: ...n page 13 of the Installation manual Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Wood Selection Storage on page 9 Bed of coals n...

Page 22: ...er or will permanently stain glass on next firing Refer to maintenance instructions NOTE Replace with 5mm ceramic glass only Service Part SRV7000 013 1 Ensure that the fire is out and the appliance is...

Page 23: ...art SRV230 0470 1 Locate the snap disc bracket assembly at the bottom left rear corner of the appliance 2 A magnet holds the bracket to the appliance Pull the bracket down away from the appliance to e...

Page 24: ...e ceramic blanket 4 Re install the baffle pieces one piece at a time Be sure the baffle boards are even with the front manifold tube and is resting on all tubes Figure 24 3 and Figure 24 4 5 To re ins...

Page 25: ...order to replace the tube channel assembly a clearance of 19 inches 483mm is required on the right side of appliance in order to remove the tubes with the appliance in place If space is not available...

Page 26: ...26 March 26 2020 7039 802B 6 Reference Materials A Service and Maintenance Log Date of Service Performed By Description of Service...

Page 27: ...Service Parts 21M ACC C Beginning Manufacturing Date Jan 2020 Ending Manufacturing Date Active R Part number list on following pages 2100 Millennium Wood Stove Advanced Combustion Control ACC 02 20 1...

Page 28: ...1 4 Qty 9 Req 832 0550 Pkg of 6 832 3040 4 2 Brick 5 3 4 x 4 1 2 x 1 1 4 Qty 3 Req SRV7128 039 4 3 Brick 8 x 4 1 2 x 1 1 4 Qty 2 Req SRV7128 022 4 4 Brick see diagram Qty 1 Req SRV7128 619 4 5 Brick...

Page 29: ...13 16 in H SRV7000 013 Y Gasket Glass Tape Field cut to Size 5 Ft Length 832 0460 Y 10 4 Frame Glass GL FRM 21M 10 5 Screw Flat Head Philips 8 32 x 1 2 Pkg of 12 220 0490 12 Y 11 Door Handle Assembly...

Page 30: ...y Side Right SRV7039 002 17 Tube Channel Top Access Cover SRV7039 114 Component Pack 7039 011 18 1 Burn Rate Control Assembly 7039 016 18 2 Spring Handle 1 4 Black SRV7000 614 Y 18 3 Timer Air Control...

Page 31: ...er Control Box W Switch SRV7000 194 Y Blower Convection 812 4900 Y Component Pack 7033 051 Snap Disc Bracket Assembly SRV7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Wire Harness Blower 7033 2...

Page 32: ...and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance...

Reviews: