background image

14

NOTE:  PIPES OVERLAP 1-3/8 INCHES (34.93mm) AT EACH JOINT.

Figure 5.
D-Series Direct Vent  Component Specifications  (5-inch inner pipe / 8 5/8-inch outer pipe)

DV-36D

5 3/4”

(146mm)

8 3/4”

(222mm)

11 3/4”

(298mm)

DV-12D

DV-09D

DV-06D

DV-48D

DV-90D

7 3/8”

(187mm)

6 5/32”

(156mm)

11 5/8”

(295mm)

11 15/16”

(303mm)

5 7/8”

(149mm)

8 5/8”

(220mm)

8 1/2”

(216mm)

6 7/16”

(164mm)

DV-45D

11 1/16”

(281mm)

6 1/2”

(165mm)

8 1/2”

(216mm)

5 1/16”

(129mm)

8 5/8”

(220mm)

35 3/4”

(908mm)

47 3/4”

(1.2m)

Summary of Contents for iLLAGE QV-PIER

Page 1: ...E FOR FUTURE REFERENCE 1 This appliance may be installed in an af termarket permanentlylocated manufac tured mobile home wherenotprohibited by local codes 2 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used WARNING IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTL...

Page 2: ...NDERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Fireplace section of the Owners Guide DO NOT USE this appliance if any part has been under water Immediately CALL a qualified service technician to inspe...

Page 3: ...ponents 22 C Vent Termination 25 Step 4 Positioning Leveling and Securing the Fireplace 27 Step 5 The Gas Control Systems 28 Step 6 The Gas Supply Line 28 Step 7 Gas Pressure Requirements 28 Step 8 Wiring the Fireplace 29 Step 9 Finishing 30 Step 10 Installing Trim Logs and Ember Material 31 Installing the Trim 31 Positioning the Logs 31 Shutter Setting 31 Placing the Ember Material 31 Step 11 Lig...

Page 4: ...LP Exploded Parts Diagram Vue éclatée des pièces Part number list on following page La liste des numéros de pièce se trouve à la page suivante Service Parts 1 2 3 4 10 6 7 9 8 6 7 9 8 12 11 5 Log Set Assembly 11 13 ...

Page 5: ...2DMS Orifice de brûleur GN 32DMS 573 800 Burner Orifice LP 1 8mm Orifice de brûleur PL 1 8mm 501 801 Junction Box Boîtier de dérivation 100 250A Piezo Ignitor Allumage Piézo 291 513 Thermopile Thermopile 060 512 Thermocouple Thermocouple 446 511 Pilot Orifice NG Orifice de veilleuse GN 446 505 Pilot Orifice LP Orifice de veilleuse PL 446 517 Pilot Assembly NG Module de veilleuse GN 485 510A Pilot ...

Page 6: ... LP Exploded Parts Diagram Vue éclatée des pièces Part number list on following page La liste des numéros de pièce se trouve à la page suivante Service Parts 6 7 9 8 6 7 9 8 1 2 3 4 10 11 11 5 Log Set Assembly 12 ...

Page 7: ... 573 800 Burner Orifice LP 1 8mm Orifice de brûleur PL 1 8mm 501 801 Junction Box Boîtier de dérivation 100 250A Piezo Ignitor Allumage Piézo 291 513 Thermopile Thermopile 060 512 Thermocouple Thermocouple 446 511 Pilot Orifice NG Orifice de veilleuse GN 446 505 Pilot Orifice LP Orifice de veilleuse PL 446 517 Pilot Assembly NG Module de veilleuse GN 485 510A Pilot Assembly LP Module de veilleuse ...

Page 8: ...codes or in the absence of local codes with the National Electric Code ANSI NFPA No 70 in the United States or to the CSA C22 1 Canadian Electric Code in Canada These models may be installed in a bedroom or bed sitting room in the U S A and Canada Approvals and Codes High Altitude Installations U L Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2 0...

Page 9: ...e instructions will void the own er s warranty and may present a fire hazard The Quadra Fire Warranty will be voided by and Hearth Home Technologies disclaims any responsibility for the following actions Installation of any damaged fireplace or vent system component Modification of the fireplace or direct vent system Installation other than as instructed by Hearth Home Technologies Improper positi...

Page 10: ...ILLE SIDE GLASS DOOR END GLASS DOOR TOP STANDOFFS TOP GRILLE TOP VENT COLLARS FRONT RIGHT SIDE LEFT SIDE 13 331mm 24 1 4 616mm 12 1 8 308mm VENT COLLARS 42 3 4 1086mm 28 7 8 735mm ELECTRICAL ACCESS 2 1 2 64mm 4 102mm 4 102mm GAS LINE ACCESS 2 1 2 6mm 36 7 8 937mm 40 3 4 1035mm 36 7 8 937mm 41 1043mm 24 1 4 616mm ...

Page 11: ...TRICAL ACCESS GAS LINE ACCESS GAS CONTROLS LABELS BOTTOM GRILLE TOP GRILLE TOP STANDOFFS GLASS DOOR 45 1143mm 13 330mm 12 1 8 308mm VENT COLLARS 24 1 4 616mm 28 7 8 733mm 2 1 2 64mm GAS LINE ACCESS 4 102mm 4 102mm 2 1 2 64mm ELECTRICAL ACCESS 43 1093mm 36 1 8 918mm 36 7 8 937mm 41 1042mm 24 1 4 616mm ...

Page 12: ...lt before or after the fireplace is set in place Framing should be positioned to accommo date wall coverings and fireplace facing material The dia gram below shows framing reference dimensions CAUTION MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING Minimum Clearances from the Vent Pipe to Combustible Materials Inches mm Vertical Sections 1 25 Horizo...

Page 13: ...1 4 41 1 2 23 1 4 45 29 7 8 QV PIER 43 1 4 44 41 1 2 23 1 4 45 29 7 8 Figure 4 Framing Dimensions NOTE DIMENSIONSSHOWNININCHES Shows center of 12 x 12 vent framing holes for top and rear venting The center of the hole is one inch 25 4mm above the center of the horizontal vent pipe B C A A C B D E QV ST QV PIER u ...

Page 14: ... inch inner pipe 8 5 8 inch outer pipe DV 36D 5 3 4 146mm 8 3 4 222mm 11 3 4 298mm DV 12D DV 09D DV 06D DV 48D DV 90D 7 3 8 187mm 6 5 32 156mm 11 5 8 295mm 11 15 16 303mm 5 7 8 149mm 8 5 8 220mm 8 1 2 216mm 6 7 16 164mm DV 45D 11 1 16 281mm 6 1 2 165mm 8 1 2 216mm 5 1 16 129mm 8 5 8 220mm 35 3 4 908mm 47 3 4 1 2m ...

Page 15: ...and the venting configuration used Identifying Vent Components The vent systems installed on this gas fireplace may in clude one two or three 90 elbow assemblies The rela tionships of vertical rise to horizontal run in vent configura tions using 90 elbows MUST BE strictly adhered to The rise to run relationships are shown in the venting drawings and tables Refer to the diagrams on the next several...

Page 16: ...16 Figure 7 Straight Up Vertical Venting STRAIGHT UP VERTICAL VENTING V FT 40 MAX 12 4 M STRAIGHT OUT HORIZONTAL VENTING H Max Run 24 610 mm Figure 8 Straight Out Horizontal Venting H V CAP ...

Page 17: ...12 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 86m 17 MAX 5 1m H 17 MAX 5 1m V H 37 MAX 11 3m Figure 10 Venting with One 90 Elbow V H 1 MIN 305mm 2 MAX 610mm 2 MIN 610mm 4 MAX 1 22m 3 MIN 914mm 6 MAX 1 86m 4 MIN 1 22m 8 MAX 2 4m V H 37 MAX 11 3m H 8 MAX 2 4m Figure 9 Venting with One 90 Elbow VENTING WITH ONE 1 90 ELBOW V H H V ...

Page 18: ... MIN 1 22m 12 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 86m 17 MAX 5 1m 17 MAX 5 1m V H 37 MAX 11 3m Figure 11 Venting with Two 90 Elbows VENTING WITH TWO 2 90 ELBOWS V FT H FT 1 MIN 305mm 3 MAX 914m 2 MIN 610mm 6 MAX 1 86m 3 MIN 914mm 9 MAX 2 7m 4 MIN 1 22m 12 MAX 3 6m 17 MAX 5 1m NOTE V V1 H 37 MAX 11 3m V H H1 H V V1 ...

Page 19: ...AX 2 7 m 4 MIN 1 22 m 8 MAX 2 48 m 12 MAX 3 6 m 8 MAX 2 48 m 17 MAX 5 1 m V H H1 37 MAX 11 3m Figure 12 Venting with Two 90 Elbows Figure 13 Venting with Two 90 Elbows VENTING WITH TWO 2 90o ELBOWS V FT H H1 FT 1 MIN 305mm 2 MAX 610mm 2 MIN 610mm 4 MAX 1 22m 3 MIN 914mm 6 MAX 1 86m 4 MIN 1 22m 8 MAX 2 4m 8 MAX 2 4m V H H1 37 MAX 11 3m V H1 H V H1 H ...

Page 20: ... m 4 MIN 1 22 m 8 MAX 2 48 m 15 MAX 4 5 m 8 MAX 2 48 m 17 MAX 5 1 m V H H1 H2 37 MAX 11 3m VENTING WITH THREE 3 90 ELBOWS V H H H1 H2 1 MIN 305 mm 2 MAX 610 mm 3 MAX 914mm 2 MIN 610 mm 4 MAX 1 22 m 6 MAX 1 86 m 3 MIN 914 mm 6 MAX 1 86 m 9 MAX 2 7 m 4 MIN 1 22 m 8 MAX 2 48 m 12 MAX 3 6 m 8 MAX 2 48 m 17 MAX 5 1 m V V1 H H1 37 MAX 11 3m VENTING WITH THREE 3 90 ELBOWS V1 V H1 H H V H1 H2 ...

Page 21: ...4 MIN 1 22m 12 MAX 3 6m 17 MAX 5 1m NOTE H H1 17 MAX 5 1m V V1 H H1 37 MAX 11 3m VENTING WITH THREE 3 90 ELBOWS V FT H H1 FT 1 MIN 305mm 3 MAX 914m 2 MIN 610mm 6 MAX 1 86m 3 MIN 914mm 9 MAX 2 7m 4 MIN 1 22m 12 MAX 3 6m 17 MAX 5 1m NOTE V V1 H H1 37 MAX 11 3m Figure 15 Venting with three 90 elbows H1 H V1 V V1 H1 H V ...

Page 22: ... 16 Follow the vent configuration tables accordingly Remove the insulation from the REAR five inch flue pull the heat shield out from outside of the firebox WARNING THE TOP HEAT SHIELD INSIDE THE FIREBOX MUST REMAIN ATTACHED IF THE VENT SYSTEM IS ATTACHED TO THE REAR STARTING COLLARS SEE FIGURE 16 Venting Out the Top Vent Remove the screws in the top vent collar seal cap and re move the top vent c...

Page 23: ...he firestops Figure 20 12 x 12 Hole and Vent Pipe Figure 21 Heat Shield Interior Exterior Firestops VENT PIPE 1 25 4 mm 12 305mm 12 305mm TRIM HEAT SHIELD IF TOO LONG ADD TO SHIELD IF TOO SHORT EXTERIOR FIRESTOP INTERIOR FIRESTOP HEAT SHIELD 3 Install Support Brackets For Horizontal Runs The vent system must be supported everyfive 5 feetofhorizontalrunbyahorizontalpipesupport To install support br...

Page 24: ...eiling using the centerpoint previously marked Frame the hole with framing lumber the same size as the ceiling joists Figure 23 Ceiling Firestop Ceiling Side If the area above the ceiling is NOT an attic position and secure the ceiling firestop on the ceiling side of the previously cut and framed hole Figure 22 Hole New Framing Members If the area above the ceiling IS an attic position and secure ...

Page 25: ...termination cap to its final exterior position on the building WARNING THE TERMINATION CAP MUST BE POSITIONED SO THAT THE ARROW IS POINTING UP For trapezoidal cap termination kits Using screws secure the cap to the exterior wall through the flanges in the cap Figure 25 Trapezoid Termination Cap WARNING VENTING TERMINALS SHALL NOT BE RECESSED INTO AWALL OR SID ING VENT TERMINATION CLEARANCES MUST B...

Page 26: ...one side and with an overhang are permitted with the dimensions specified for vinyl or non vinyl siding and soffits 1 There must be 3 feet minimum between termination caps 2 All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap 3 All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the terminatio...

Page 27: ...e of the building Roof Pitch H min ft flat to 6 12 1 0 6 12 to 7 12 1 25 over 7 12 to 8 12 1 5 over 8 12 to 9 12 2 0 over 9 12 to 10 12 2 5 over 10 12 to 11 12 3 25 over 11 12 to 12 12 4 0 over 12 12 to 14 12 5 0 over 14 12 to 16 12 6 0 over 16 12 to 18 12 7 0 over 18 12 to 20 12 7 5 over 20 12 to 21 12 8 0 Figure 27 Minimum Height from Roof to Lowest Discharge Opening To seal the roof hole and to...

Page 28: ...the shut off valve When attaching the pipe support the control so that the lines are not bent or torn Step 7 Gas Pressure Requirements Pressure requirements for Hearth Home Technolo gies gas fireplaces are shown in the table below Pressure Natural Gas Propane Minimum 5 0 inches 11 0 inches Inlet Pressure w c w c Maximum Inlet 14 0 inches 14 0 inches Gas Pressure w c w c Manifold 3 5 inches 10 0 in...

Page 29: ...manently installed Wall Switch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace ON OFF switch pigtails CAUTION LABEL ALL WIRES PRIOR TO DISCONNEC TION WHEN SERVICING CONTROLS WIRING ERRORS CANCAUSEIMPROPERANDDANGEROUSOPERATION VERIFY PROPER OPERATION AFTER SERVICING BLACK S2 ON OFF ON O...

Page 30: ...ED A 300 F MINIMUM SEALANT MATE RIAL MUST BE USED THESE JOINTS ARE NOT RE QUIRED TO BE SEALED ONLY NON COMBUSTIBLE MATERIAL USING 300 F MINIMUM ADHESIVE IF NEEDED CAN BE APPLIED AS FACING TO THE FIRE PLACE SURROUND SEE THE DIAGRAM BELOW NOTE Sheetrock or other combustible material such as wood can be placed on the top edge of the fireplace A 1 2 inch gap along the side must be maintained Hearth Ex...

Page 31: ...Place dime size pieces of ember material about 1 2 inch apart near port holes in burner top Do NOT press em bers into burner ports Cover the top of the burner with a single layer of ember material For best performance do NOT place embers on the ports at the rear of the burner Save the remaining ember materials for use during fire place servicing The bag of embers provided is sufficient for 3 to 5 ...

Page 32: ...t the control in the PILOT position turn the control knob counter clockwise to the PILOT position 6 To light the pilot press the control knob and then press the red or black piezo button once every second The piezo makes a clicking sound It may be necessary to repeat this step If the pilot does not light after 10 seconds go back to step 2 The control knob should be held down for a MINUTE after pil...

Page 33: ... in the gas supply lines When first lighting the fireplace it will take a few minutes for the lines to purge themselves of this air Once the purging is complete the fireplace will light and will operate normally Subsequent lightings of the fireplace will not require this purging of air from the gas supply lines unless the gas valve has been turned to the OFF position in which case the air would ha...

Page 34: ...ontrol compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a visual check of your fireplace s flame patterns Make sure the flames are steady not lifting or floating The thermopile thermocouple tips should be covered with flame See Figure 29 Checking Vent System Frequency Be...

Page 35: ...the pilot and hold the valve knob in If the millivolt reading is less than 15mV replace the thermocouple b Defective valve If the thermocouple is producing more than 15 millivolts replace faulty valve 3 The pilot is burning there is no gas burner the valve knob is in the ON position and the ON OFF switch is in the ON position a ON OFF switch or wires defective Check the ON OFF switch and wires for...

Page 36: ... downwards lope is 1 4 inch d Glass too loose and air tight packet leaks in corners after usage Tighten the corner e Bad thermopile or thermocouple Replace if necessary f Improper vent cap installation Check for proper installation and freedom from debris or blockage 6 Glass soots a Flame impingement Adjust the log set so that the flame does not excessively impinge on it b Improper venturi setting...

Page 37: ...l accessories Adjustments regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will not be covered The replacement of consumer replaceable items and installation of upgraded component parts do not quality for a service call fee and will not be covered This limited Lifetime Warranty does not extend to or include surface finish on the appliance door gasketing ...