C. Negative Pressure
D. Tools And Supplies Needed
%HIRUHEHJLQQLQJWKHLQVWDOODWLRQEHVXUHWKHIROORZLQJWRROV
DQGEXLOGLQJVXSSOLHVDUHDYDLODEOH
-
Reciprocating saw
-
Pliers
-
+DPPHU
-
Phillips screwdriver
-
)ODWEODGHVFUHZGULYHU
-
3OXPEOLQH
-
Level
-
0LVFVFUHZVDQGQDLOV
-
)UDPLQJPDWHULDO
-
+LJKWHPSFDXONLQJPDWHULDO
-
Gloves
-
)UDPLQJVTXDUH
-
(OHFWULFGULOODQGELWV
-
Safety glasses
-
7DSHPHDVXUH
-
VRFNHWRUZUHQFK
-
LQOHQJWKRUVHOIGULOOLQJVFUHZV
E. Inspection of Appliance and Components
•
5HPRYH DSSOLDQFH DQG FRPSRQHQWV IURP SDFNDJLQJ
DQGLQVSHFWIRUGDPDJH
•
5HSRUWWR\RXUGHDOHUDQ\SDUWVGDPDJHGLQVKLSPHQW
• Read all the instructions before starting the
installation. Follow these instructions carefully
during the installation to ensure maximum safety
DQGEHQH¿W
1HJDWLYHSUHVVXUHUHVXOWVIURPWKHLPEDODQFHRIDLUDYDLODEOH
IRUWKHDSSOLDQFHWRRSHUDWHSURSHUO\,WFDQEHVWURQJHVWLQ
lower levels of the house.
Causes include:
•
([KDXVWIDQVNLWFKHQEDWKHWF
• Range
hoods
•
&RPEXVWLRQ DLU UHTXLUHPHQWV IRU IXUQDFHV ZDWHU
DSSOLDQFHVDQGRWKHUFRPEXVWLRQDSSOLDQFHV
• Clothes
dryers
•
Location of return-air vents to furnace or air conditioning
•
,PEDODQF9$&DLUKDQGOLQJV\VWHP
•
8SSHUOHYHODLUOHDNVVXFKDV
-
Recessed lighting
-
Attic hatch
-
Duct leaks
7RPLQLPL]HWKHHႇHFWVRIQHJDWLYHDLUSUHVVXUH
• Install optional outside air kit with the intake facing
prevailing winds during the heating season
•
(QVXUH DGHTXDWH RXWGRRU DLU IRU DOO FRPEXVWLRQ
DSSOLDQFHVDQGH[KDXVWHTXLSPHQW
•
Ensure furnace and air conditioning return vents are not
ORFDWHGLQWKHLPPHGLDWHYLFLQLW\RIWKHDSSOLDQFH
•
Avoid installing the appliance near doors, walkways or
VPDOOLVRODWHGVSDFHV
•
5HFHVVHGOLJKWLQJVKRXOGEHD³VHDOHGFDQ´GHVLJQ
•
Attic hatches weather stripped or sealed
•
$WWLF PRXQWHG GXFW ZRUN DQG DLU KDQGOHU MRLQWV DQG
VHDPVWDSHGRUVHDOHG
•
%DVHPHQWLQVWDOODWLRQVVKRXOGEHDYRLGHG
Asphyxiation Risk.
• Negative pressure can cause spillage
RI
FRPEXVWLRQ
IXPHV
VRRW
DQG
FDUERQPRQR[LGH
•
Appliance needs to draft properly for safety.
WARNING
!
Fire Risk.
,QVSHFWDSSOLDQFHDQGFRPSRQHQWVIRUGDPDJH
'DPDJHGSDUWVPD\LPSDLUVDIHRSHUDWLRQ
•
'R127LQVWDOOGDPDJHGFRPSRQHQWV
•
'R127LQVWDOOLQFRPSOHWHFRPSRQHQWV
•
'R127LQVWDOOVXEVWLWXWHFRPSRQHQWV
5HSRUWGDPDJHGSDUWVWRGHDOHU
WARNING
!
•
,QVWDOODWLRQDQGXVHRIDQ\GDPDJHGDSSOLDQFH
•
0RGL¿FDWLRQRIWKHDSSOLDQFH
•
,QVWDOODWLRQ RWKHU WKDQ DV LQVWUXFWHG E\ +HDUWK +RPH
Technologies.
•
,QVWDOODWLRQDQGRUXVHRIDQ\FRPSRQHQWSDUWQRWDSSURYHG
E\+HDUWK +RPH7HFKQRORJLHV
•
2SHUDWLQJ DSSOLDQFH ZLWKRXW IXOO\ DVVHPEOLQJ DOO
FRPSRQHQWV
•
2SHUDWLQJDSSOLDQFHZLWKRXWOHJVDWWDFKHGLIVXSSOLHGZLWK
DSSOLDQFH
•
'R 127 2YHU ¿UH ,I DSSOLDQFH RU FKLPQH\ FRQQHFWRU
JORZV\RXDUHRYHU¿ULQJ
$Q\VXFKDFWLRQWKDWPD\FDXVHD¿UHKD]DUG
Fire Risk.
+HDUWK +RPH 7HFKQRORJLHV GLVFODLPV DQ\
UHVSRQVLELOLW\IRUDQGWKHZDUUDQW\ZLOOEHYRLGHG
E\WKHIROORZLQJDFWLRQV
WARNING
!