4/12
433-1390K
Page 7
G. Glass Specifications
This fireplace is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
NOTICE:
This installation must conform with local codes. In
the absence of local codes you must comply with the UL127,
(UM) 84-HUD and NFPA211 in the U.S.A. and the ULC
610-M87 and CAN/CSA-B365 Installation Codes in Canada.
WARNING! Risk of Fire!
Hearth & Home Technologies
disclaims any responsibility for, and the warranty and
agency listing will be voided by the following actions.
DO NOT:
• install or operate damaged fireplace
• modify fireplace
• install other than as instructed by Hearth & Home
Technologies
• operate the fireplace without fully assembling all
components
• overfire
• install an unvented gas log set
• install any component not approved by Hearth & Home
Technologies
• install parts or components not Listed or approved
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualified
installer, service agency or your dealer.
• Materials which will not ignite and burn, composed of
any combination of the following:
- Steel
- Iron
- Brick
- Tile
- Concrete
- Slate
- Glass
- Plasters
• Materials reported as passing
ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace at 750° C
• Materials made of or surfaced with any of the following
materials:
- Wood
- Compressed paper
- Plant fibers - Plastic
• Any material that can ignite and burn; flame proofed or
not, plastered or un-plastered
NOTICE:
This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code ANSI/
NFPA 70-latest edition
or the
Canadian Electric Code
CSA C22.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in damp locations.
Electrical Codes are used only if the unit is supplied with
a fan.
F. Electrical Codes
E. Combustible Materials
D. Non-Combustible Materials
WARNING!
Improper installation, adjustment, altera-
tion, service or maintenance can cause injury or prop-
erty damage. Refer to the owner’s information manual
provided with this fireplace. For assistance or additional
information consult a qualified installer, service agency
or your dealer.
EPA# and Original Date:
#571 4-1-03
EPA Certified:
3.1 grams per hour
Efficiency:
up to 77%
BTU Output
with EPA test fuel:
58,000 / hr.
with Cord Wood:
90,000 / hr.
Heating Capacity:
up to 3,500 sq ft
Vent Size:
8 inches
Max Wood Length:
24 inches
Fuel:
Cord Wood
Shipping Weight:
670 lbs
Firebox Size
3.7 cubic feet
C. BTU & Efficiency Spectifications