2
7038-207G
September 28, 2016
5700 STEP TOP ACC
A. Sample of Serial Number / Safety Label
LOCATION: Back of appliance
A B C D E F G H
SINGLE WALL PIPE
12.5 (318) 10.5 (267) 25.5 (648) 15 (381) 2 (51) 12 (305) 45 (1143) N/A
DOUBLE WALL PIPE
9.5 (241) 7.5 (191) 25.5 (648) 15 (381) 2 (51) 12 (305) 45 (1143) N/A
INSTALLATION: HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP
INSTALLATION:
HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
SINGLE WALL PIPE
9.5 (241) 7.5 (191) 25.5 (648) 15 (381)
*
*
45 (1143) 18 (457)*
DOUBLE WALL PIPE
9.5 (241) 7.5 (191) 25.5 (648) 15 (381)
*
*
45 (1143) 13 (330)
SINGLE WALL PIPE
9.5 (241) 7.5 (191) 25.5 (648) 15 (381) 2 (51) 12 (305) 45 (1143) 18 (457)*
DOUBLE WALL PIPE
9.5 (241) 7.5 (191) 25.5 (648) 15 (381) 2 (51) 12 (305) 45 (1143) 13 (330)
INSTALLATION: ALCOVE
- Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT** listed factory-built
Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48
inches (1219mm) and the referenced alcove clearances.
(**In Canada must comply with Standard CAN/ULC-S629-M87 for the 650
o
C Factory-built chimney.)
(**Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650
o
C cheminée bâtit en usine.)
DOUBLE WALL PIPE
10.5 (268) 8.5 (216) 25.5 (648) 15 (381) N/A N/A 45 (1143) *
*
SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED
SPÉCIFICATIONS DE LA VENTILATION:
MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de
minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en usine
UL103HT* de Classe "A", adéquate pour usage avec les combustions solides, ou une
cheminée de briques, avec espaces libres référés.
MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air
isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe "A:, ou
une cheminée de briques, avec espaces libres alloués.
MAISON MOBILE: Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk
Metalbestos DS ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les
espaces libres pour mur double comme mentionné ci-bas.
MIN CLEARANCES TO COMBUSTIBLE MATERIALS: Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to inside diameter of flue collar.
LISTED ROOM HEATER, SOLID FUEL TYPE.
ALSO FOR USE IN MOBILE HOMES. (UM)
84-HUD .
"For Use with Solid Wood Fuel Only"
1445 N. Highway, Colville, WA 99114
www.quadrafire.com
Install and use only in accordance with manufacturer's
installation and operating instructions. Contact local
building or fire officials about restrictions and
installation inspections in your area. Do not obstruct
the space beneath heater.
For use only with leg and pedestal options intended
for this model, refer to owner’s manual for appropriate
part numbers and installation instructions.
SUITABLE FOR MOBILE HOME INSTALLATION
WARNING - For Mobile Homes: Do not install in a
sleeping room. An outside combustion air inlet must
be provided and unrestricted while unit is in use. The
structural integrity of the mobile home floor, ceiling
and walls must be maintained. The stove needs to be
properly grounded to the frame of the mobile home.
Components required for mobile home installation:
Outside Air Kit, Part Number OAK-ACC.
Refer to manufacturer's instructions and local codes
for precautions required for passing chimney through
a combustible wall or ceiling and maximum offsets.
Inspect and clean chimney frequently - Under Certain
Conditions of Use, Creosote Buildup May Occur
Rapidly.
Do not connect this unit to a chimney serving another
appliance.
Optional Components: Optional Blower, Part
BK-ACC.
Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz.
Route power cord away from unit. Do not route cord
under or in front of appliance.
DANGER: Risk of electrical shock. Disconnect power
supply before servicing.
Replace glass only with 5mm ceramic available from
your dealer.
Do not use grate or elevate fire. Build wood fire
directly on hearth.
Do not overfire - if heater or chimney connector glows,
you are overfiring.
OPERATE ONLY WITH DOORS CLOSED
Open only to add fuel to the fire.
Do NOT operate before fully assembling components.
WARNING: Only used approved wood fuel listed in
owners manual. Burning any other fuel will void
warranty.
CAUTION
:
U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2015
particulate emission standards at 2.3 G/HR EPA Methods 28 and 5G. Not approved for
sale after May 15, 2020. This wood heater needs periodic inspection and repair for
proper operation. Consult the owner’s manual for further information. It is against federal
regulations to operate this wood heater in a manner inconsistent with the operating
instructions in the owner’s manual.
2016 2017 2018 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.
PREVENT HOUSE FIRES
FLOOR PROTECTION
:
Floor protector must be a 1 inch min. thickness, ("k" value =
.49, R value = 2.04) non-combu
stible material or equivalent,
extending beneath heater and to front/sides/rear as indicated
on the diagram below. Exception: Non-combustible floor
protections must extend beneath the flue pipe when installed
with horizontal venting and extend 2 inches (51mm) beyond
each side.
Report
/
Rapport
#061-S-73-6.2
TESTED TO:
/ TESTÉ À:
UL 1482-11 (R2015), ULC S627-00
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP
FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS
VENT SPECIFICATIONS:
SINGLE WALL:
Six inch (6 inches) (152mm) diameter, minimum 24 MSG black
or blued steel connector pipe, with a listed factory-built UL103HT* Class "A"
chimney, suitable for use with solid fuels, or a masonry chimney, and the
referenced clearances.
DOUBLE WALL:
Six inch (6 inches) (152mm) diameter, listed double wall air
insulated connector pipe with listed factory-built UL103HT* Class "A" chimney,
or a masonry chimney and the referenced clearances
MOBILE HOME:
Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos
DS or Security DL double wall connector pipe. Must be equipped with a spark
arrestor. Apply double wall clearances below when installing unit.
R
7038-162H
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT
PEUT CAUSER DES BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR
L'ÉTIQUETTE ET LES INSTRUCTIONS.
ATTENTION:
A
PPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE
COMBUSTIBLE SOLIDE, POUR USAGE DANS LES
MAISONS MOBILES. (UM) 84 HUD. "Pour Usage Avec
Bois Solide Seulement"
Installez et utilisez en accord avec les instructions
d'installation et d'opération du fabricant. Contactez le
bureau de la construction ou le bureau des incendies au
sujet des restrictions et des inspections d'installation dans
votre voisinage. Ne pas obstruez l'espace en dessous de
l'appareil.
CONVIENT POUR UNE INSTALLATION MAISON MOBILE
AVIS - Pour Les Maisons Mobiles: Ne pas installer dans
une chambre à coucher. Un tuyau extérieur de
combustion d'air doit être installé et ne doit pas être
obstrué lorsque l'appareil est en usage. La structure
intégrale du plancher, du plafond et des murs de la
maison mobile doit être maintenue intacte. L'appareil de
chauffage doit être fixé à la charpente de la maison
mobile. Les composants requis pour l'installation des
maisons mobiles: Assemblage d'air extérieur, Numéro de
Pièce OAK-ACC.
Référez vous aux instructions du fabricant et des codes
locaux pour les précautions requises pour passer une
cheminée à travers un mur ou un plafond combustibles,
et les compensations maximums.
Inspectez et nettoyez la cheminée fréquemment. Sous
certaines conditions, il se peut que la créosote
s'accumule rapidement.
Ne pas connecter cet appareil à une cheminée servant un
autre appareil.
Composants Optionnels: Ventilateur Optionnel, Pièce
BK-ACC.
Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.
Éloignez le fil électrique de l'appareil. Ne pas faire passer
le fil électrique au dessus ou en dessous de l'appareil.
DANGER: Il y a risque de décharge électrique.
Déconnectez le fil électrique de la prise de contact avant
le service.
Remplacez la vitre seulement avec une vitre céramique
de 5 mm disponible chez votre fournisseur.
N'élevez pas le feu. Bâtissez le feu de bois directement
sur l'âtre.
Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau
de cheminée rougissent, vous surchauffez.
Opérez l'appareil seulement lorsque la porte de
chargement est fermée. Ouvrez la porte seulement
lorsque vous devez ajouter des combustibles dans le feu.
PRÉVENTION DES FEUX DE MAISON
PROTECTION DU PLANCHER:
Le protecteur de plancher doit être d'un minimum de 1 inch
(25mm) d'épaisseur, ('k" value = .49,
R value = 2.04) d
e matériel
incombustible ou équivalent, s'étendant du dessous de l'appareil
de chauffage à l'avant, aux cotés et à l'arrière comme indiqué
sur le diagramme suivant. Exception: Les protections
incombustibles du plancher doivent s'étendre en dessous du
conduit de cheminée lorsqu'installées avec une ventilation à
l'horizontale et s'étendre de 2 inches (51mm) de chaque côté.
ESPACES LIBRES MIN DES MATÉRIAUX COMBUSTIBLES:
En Pouces & (millimètres)
NOTE: Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur
de l'entrée du conduit.
BACKWALL/SIDE
WALL/
MUR
ARRIÈRE/MUR
DE CÔTÉ
90 OFF TOP UP & OUT
CEILING CLEARANCE/
ESPACE LIBRE DU
DESSUS DE
L'APPAREIL AU
PLAFOND AVEC 90 DE
COURBURE
CORNER
INSTALLATION/
INSTALLATION
DU COIN
ALCOVE TOP
VIEW /
VUE DU HAUT DE
L'ALCÔVE
ALCOVE SIDE
VIEW /
VUE DE CÔTÉ
DE L'ALCÔVE
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
CONDUIT DU MUR SIMPLE
CONDUIT DU MUR DOUBLE
INSTALLATION: 90
o
ELBOW OFF TOP OF STOVE THROUGH BACKWALL
INSTALLATION: 90
o
DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIERE
INSTALLATION: ALCÔVE - Six pouces (6 pouces) (152mm) de diamètre listé air isolé tuyau de raccordement à double paroi avec UL103 HT ** cotée Classe
usine construite "A" cheminée ou une cheminée de maçonnerie. (Mobile Home doit être équipé d' un pare-étincelles.) Profondeur maximale de Alcove ne doit
pas être plus de 48 pouces (1219mm) et les dégagements en alcôve référencés.
CONDUIT DU MUR DOUBLE
A
B
C
D
E
F
E
F
G
H
C
D
G
A
B
16" from glass
8"
USA
Fuel loading door
33-1/2”
minimum
45-7/8”
minimum
CANADA
203mm (8")
203mm
(8")
203mm
(8")
457mm (18")
1394mm
(54-7/8")
minimum
1092mm (43")min
Manufactured by:
Fabriqué par:
INSTALLATION: FULL VERTICAL INSTALLATION:
ENTIÈREMENT VERTICALE
CONDUIT DU MUR DOUBLE
SERIAL NO.
/
NUMÉRO DE SÉRIE
CV009
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
5700 Step Top ACC
STOVE TO CEILING CLEARANCE/
ESPACE LIBRE DU POÊLE AU
PLAFOND
CONDUIT DU MUR SIMPLE
CONDUIT DU MUR SIMPLE
CONDUIT DU MUR DOUBLE
Ne mettez PAS le poêle en marche tant que tous les
composants n’ont pas été entièrement assemblés.
ATTENTION:
Seulement utilisé carburant approuvé
indiquée dans le manuel des propriétaires. La
combustion d'autres combustibles annulera la garantie.
Made in U.S.A.
of US and
imported parts.
Fabriqué aux États-Unis-d’Amérique par
des pièces d’origine américaine et pièces
importées.
Serial No.
Model
Name
Test Lab &
Report No.
Mfg. Date
S A
M P
L E
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction