background image

 

www.avsl.com

                                                                                                        160.448UK Manual 

Specifications: 
 

Power supply 

220-240Vac, 50/60Hz (IEC) 

Power consumption 

1200W 

Fuse rating 

F5A 

DMX Channels 

2Ch 

Warm up time 

3-5 minutes 

Remote control connection 

5 pin DIN 

Remote control frequency 

433Mhz 

Fog output (approx.) 

7500 cu.ft per minute 

Fluid capacity 

1.2 litre (fog fluid), 3 litre (water) 

Dimensions 

510 x 360 x 260mm 

Weight 

9.3kg 

 
Troubleshooting: 

 

No power to main unit  

Check mains voltage is correct and socket is switched on 

or wired controller 

Check IEC lead is OK and connected properly 

 

Check mains fuse in IEC connector and fuse in plug top 

 

If fuse blowing repeatedly, refer to qualified service personnel 

Power to unit but no 

Check fluid level in tank 

fog output in manual 

If fluid is OK and pump working, the lines may be blocked 

or continuous mode  

Check that output is not set to zero on the control panel 

 

Check that output is not switched off on the key fob remote 

 

If blocked, clean with fog machine cleaner & distilled water 

 

Check that if DMX mode is selected, the DMX channel is correct 

 

In DMX mode, check that fog output is not set to zero 

Fog output from unit  

Ensure you are using the correct fog fluid for the unit 

drifts upwards 

Ensure there is sufficient water in the reservoir and that its not 

overfilled 

 

 

 
 

 
 

 

 

  

 

 

 

This product is classed as Electrical or Electronic equipment and should not be disposed with other household or 

commercial waste at the end of its useful life. The goods must be disposed of according to your local council guidelines. 

 
Errors and omissions excepted.

  

Copyright© 2023 AVSL Group Ltd, Unit 2 Bridgewater Park,                                                  AVSL (Europe) Ltd, Unit 3D North Point House, 
Taylor Road, Trafford Park, Manchester. M41 7JQ. 

 

 

       North Point Bus. Park, New Mallow Road, Cork, Ireland. 

Summary of Contents for STRATUS-1200

Page 1: ...y delivers a ground hugging flowing mist from standard fog fluid and water perfect for stages theatres and themed events The main unit has a removable fluid tank and easy access water reservoir with drain tap and can be operated by a wired digital control panel separate RF remote or 2 channel DMX connection if required Produces an impressive ground hugging mist effect Works using only standard fog...

Page 2: ... parts inside do not open the case 5 Allow the unit to acclimatise to room temperature before operating 6 The Stratus 1200 has a built in fluid container and reservoir so should be operated in an upright position Ensure that the unit is positioned on a stable non slip surface Safety and Cleaning 1 Check for correct mains voltage and condition of IEC lead before connecting to mains 2 This unit must...

Page 3: ...alue START STOP Press to start stop continuous fog DOWN Press to decrease current menu value MANUAL Press and release for fog on demand Setting Up 1 Unpack the Stratus 1200 unit 2 Unscrew the top cap of the tank and remove to fill with fog fluid 3 Replace the bottle and screw the cap securely making sure that the pipe is fed down to the bottom of the bottle to ensure a consistent flow of fluid ...

Page 4: ...on Content Heating status Warming up Unit is warming up please wait Ready to fog Unit is ready to use Manual volume adjust Set 1 100 Set manual fog output low to high Interval Set 1 900 Set continuous fog intervals low to high Duration Set 1 200 Set continuous fog duration Volume Set 1 100 Set continuous fog output low to high Wind Set 1 100 Set fan speed low to high DMX512 Set 1 512 Set required ...

Page 5: ...s may be blocked or continuous mode Check that output is not set to zero on the control panel Check that output is not switched off on the key fob remote If blocked clean with fog machine cleaner distilled water Check that if DMX mode is selected the DMX channel is correct In DMX mode check that fog output is not set to zero Fog output from unit Ensure you are using the correct fog fluid for the u...

Reviews: