152.766UK User Manual

 

 

Trouble shooting: 

 

No power output 

Check mains power is connected correctly and mains cable 

is in good condition. 
Check fuse is in working condition, if fuse continually blows 
stop use immediately and refer unit to qualified personnel. 

Power on but no output 

Check dip switch 10 is not switched on. 
Check key switch is switched on. 
Check interlock switch if there is one connected. 
If ambient temperature is low, laser head may take up to 
30 min to warm up for max output. 
Ensure mic sensitivity is turned up if sound-to-light mode is 

selected. 

DMX mode no output 

Check correct DMX lead is used (balanced XLR). 
Check DMX controller is not in blackout mode. 
Check if DMX controller has polarity switch and is correctly 
selected. 
Check laser DMX initial address number is set correctly on 
dip switch and switch 10 is switched on. 
Ensure DMX lead is not running along with high voltage 

cable. 
Ensure channel 1 and channel 12 value is not set at 0.  
Try alternative controller to ensure it is not faulty. 

 

 

 
 

 
 

This product complies with laser safety standard EN60825-1 2007. 

 

 

  

 

 

This product is classed as Electrical or Electronic equipment and should not be disposed with 

other household or commercial waste at the end of its useful life. The goods must be disposed of 

according to your local council guidelines. 

 

 
 
 

Errors and omissions excepted.  

Copyright©  2014. AVSL Group Ltd

 

Summary of Contents for MITO

Page 1: ...MITO Mito RGB 1420mW RGB Effects Laser Item ref 152 766UK User Manual...

Page 2: ...our mixing can produce up to 7 colours Auto sound to light pattern select and 23 channel DMX operation modes Two head laser system modulation High power RGB laser heads totaling 1 42W red 300mW green...

Page 3: ...rected away from people and objects that are able to reflect the emission towards people In this regard the separation distances of 3 metres vertically and 2 5 metres horizontally cited in HSG95 and s...

Page 4: ...mains lead to connect to the mains power supply To wire directly to the mains earth wiring must be connected for safety Please refer to below colour coding for the correct wiring Wire colour Connecti...

Page 5: ...e no end user serviceable parts within the unit To maintain workable condition of the unit we are advice to remove collected dust from the unit on a regular basis Before cleaning or dusting always ens...

Page 6: ...when DMX signal present 4 XLR socket for DMX signal in 5 XLR plug for DMX signal loop out 6 Dip switch to switch between auto sound to light and DMX mode also serves as DMX initial address setting 7 B...

Page 7: ...h on and switch 10 must be switch off Sound to light 1 Sound to light 2 Sound to light 3 To switch to DMX mode switch 10 must be switched on and switches 1 9 can be used to set the initial DMX address...

Page 8: ...e full pattern size 151 156 S2L warp mode reduce pattern size to 50 151 and 154 25 152 and 155 12 5 153 and 156 157 200 S2L warp mode full pattern size 201 230 Auto show mode 230 255 S2L show mode CH2...

Page 9: ...ntical ch7 controls pattern1 ch18 controls pattern 2 0 63 Manual flip around vertical axis 64 127 Auto S2L control by ch1 contracting wave effect around vertical axis 128 159 Auto S2L control by ch1 s...

Page 10: ...Uniform colour change 192 255 Graduate colour change by parts CH23 0 31 Grating effect 1 32 47 Grating effect 2 48 63 Grating effect 3 64 79 Grating effect 4 80 95 Grating effect 5 96 111 Grating effe...

Page 11: ...k correct DMX lead is used balanced XLR Check DMX controller is not in blackout mode Check if DMX controller has polarity switch and is correctly selected Check laser DMX initial address number is set...

Reviews: