background image

User Manual 

 

 

 

153.772 / 153.775

 

 

10. Mounting instruction : 

The fixture may be mounted in any position provide there is adequate room for ventilation. 

It is important never to obstruct the fan or vents pathway. Mount the fixture using clamp. Adjust angle 

of the fixture loosening both knobs and tilting the fixture. After finding desired position, retighten both 

knobs. 

When  selecting  installation  location,  take  into  consideration  lamp  replacement  access  and  routine 

maintenance. Safety cables must always be used. 

Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature 

changer or restricted ventilation.   

 

11. Dip Switch Setting & Function   

 

ON

 

OFF

 

FUNCTION

 

12

 

1,2,3,4,5,6,7,8,9,10,11

 

Manual colour selection

 

1, 12

 

2,3,4,5,6,7,8,9,10,11

 

50% Red

 

1,2,12

 

3,4,5,6,7,8,9,10,11

 

100% Red 

 

3, 12

 

1,2,4,5,6,7,8,9,10,11

 

50% Green

 

3,4,12

 

1,2,5,6,7,8,9,10,11

 

100% Green

 

5,12

 

1,2,3,4,6,7,8,9,10,11

 

50% Blue

 

5,6,12

 

1, 2, 3, 4, 7, 8, 9, 10, 11

 

100% Blue

 

1,2,3,4,5,6,12

 

7, 8, 9, 10, 11

 

White

 

1,2,5,6,12

 

3,4,7,8,9,10,11

 

Purple 

 

3,4,5,6,12

 

1,2,7,8,9,10,11

 

Cyan

 

1,2,3,4,12

 

5,6.7,8,9,10,11

 

Yellow

 

9

 

1,2,3,4,5,6,7,8,10,11,12

 

Master sound activity with timeout 

Slave units dip “ 1” =ON

 

Nil

 

1,2,3,4,5,6,7,8,9,10,11,12

 

Sound activated (standalone)

 

9,12

 

1,2,3,4,5,6,7,8,10,11

 

Master  sound  activated  strobe  with 

timeout

 

9,10

 

1,2,3,4,5,6,7,8,11,12

 

Master 

illusion 

colour 

changing 

(12colour circulate fade in & fade out)

 

9,11

 

1,2,3,4,5,6,7,8,10,12

 

Master  colour changing effect 

(slow )

 

9,10,11

 

1,2,3,4,5,6,7,8,12

 

Master  colour changing effect 

(fast )

 

1-9

 

10,11,12

 

DMX address select

 

 

 

 

12.

 

DMX Controlling : 

Reviews: