background image

User Manual – MW-36 

                            150.450UK

 

 

 

4.

 

Caution : 

For your safety, please kindly pay attention to all of the warnings below:   

 

 

Always plug in the power plug last and disconnect from the mains, when 

the device is not in use or before cleaning. 

 

Do not install and operate the device in rain or extreme heat, moisture 

or dusty environments. 

 

This device is for indoor use only an din a dry environment. 

 

Do not switch on immediately but wait until it reaches to room 

temperature, if the device has been exposed to drastic temperature 

fluctuations. 

 

Do not shake the device and avoid brute force when installing or 

operating 

 

Do not spread the smoke or bubble of effect machine directly to the 

device. 

 

Do not use the device during thunderstorms and please disconnect the 

power. 

 

Do not use solvents or aggressive detergent to clean the device. Use a 

soft and clean cloth. 

 

Do not modify the device or the connected power cord without 

authorization. 

 

Use appropriate safety-rope for safety. 

 

Do not stare to the light. 

 

The symbol 

determines the minimum distance from lighted 

objects. The minimum distance between light-output and the 

illuminated surface must be more than 0.5m. 

 

 

User Manual – MW-36 

                            150.450UK

 

 

 

14. DMX Controlling : 

 

DMX Channel 

Function & Value 

Channel 1 

000-255 PAN Scan (0° - 540°) 

Channel 2 

000-255 Tilt Scan (0° - 280°) 

Channel 3 

000-255 PAN Fine (16 BIT) 

Channel 4 

000-255 Tilt Fine (16 BIT) 

Channel 5 

000-255 Pan & Tit speed (Fast - Slow) 

000-006 No function 

007-065 Strobe from (Slow to fast) 

066-069 No function 

070-128 Thunder strobe (Slow to fast) 

129-132 No Function 

133-191 Bright strobe (Slow to fast) 

192-195 No Function 

Channel 6 

196-255 Dimmer strobe (Slow to fast) 

Channel 7 

000-255 Master dimmer 

Channel 8 

000-255 Red brightness 0-100% 

Channel 9 

000-255 Green brightness 0-100% 

Channel 10 

000-255 Blue brightness 0-100% 

000-006 No function 

007-044 Eight fixed colours 

045-049 No function 

050-094 Eight colours changing jumping (9 classes) 

095-099 No function 

100-149 Eight colours changing gradually (Slow to fast) 

150-154 No function 

Channel 11 

155-166 Red + Green from dim to bright 

Summary of Contents for MW-36W

Page 1: ...WWW QTXLIGHT COM MW 36W TRI Colour Moving head User Manual 150 450UK ...

Page 2: ...via 3 pin XLR Ultra bright producing rich colour Auto and sound activated programs 12 channel DMX Colour mode RGB 0 100 shutter dimmer Pan tilt pan tilt speed pan fine tilt fine Fan cooled Mounting bracket supplied We recommend that this product is used within the guidelines HSG95 Caution Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty User...

Page 3: ...se keep the original package and invoice for any possible replacement or returned demand 3 Installation Every person involved with the installation operation and maintenance of this device should be qualified and follow the instructions of this User Guide We recommend that this product is not used for audience scanning and should be used within the guidelines of radiation of lasers used for displa...

Page 4: ...se appropriate safety rope for safety Do not stare to the light The symbol determines the minimum distance from lighted objects The minimum distance between light output and the illuminated surface must be more than 0 5m User Manual MW 36 150 450UK 9 14 DMX Controlling DMX Channel Function Value Channel 1 000 255 PAN Scan 0 540 Channel 2 000 255 Tilt Scan 0 280 Channel 3 000 255 PAN Fine 16 BIT Ch...

Page 5: ...7 1 if the unit is not functional Check if main power is on and fuse 7 2 if the unit is not reacting to music check the unit is in M SO mode on the display 8 Replacing Fuse Disconnect from the main power supply first then remove the fuse holder above the IEC Socket to reveal the fuse Replace the correct fuse rating as stated on lighting or user guide Then lock the fuse holder cover back into place...

Page 6: ...ut Cleaning frequently depends on the environment in which the fixtures operates damp smoky or particularly dirty surroundings can require cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days User Manual MW 36 150 450UK 7 11 Layout for the 150 450UK 1 DMX Input 2 AC Power input 3 Power switch on off 4 DMX Output 12 Digital Display Setting Function FUN Func...

Reviews: