If there is no entry in the network destination column that starts with 169.254.0.0
(highlighted above), add a route using
route add 169.254.0.0 mask 255.255.0.0 10.10.0.20 metric 20
where 10.10.0.20 is replaced with the IP address of the interface (network card) in your
computer that is to communicate with the AN-X2.
Repeat the route print command and confirm that the table now has an entry similar to the
one shown.
Now try pinging the AN-X2 at 169.254.42.84. You should now be able to access it using
a browser to set the desired Ethernet configuration.
When you add a route in Windows and you want it to be 'persistent', use the -p option:
route –p add 169.254.0.0 mask 255.255.0.0 10.10.0.20 metric 20
That puts the route in the registry and it is added at each start up.