QSOURCES INFRA User Instruction Download Page 7

5. Prevent electrical damage

The amplifier is internally protected against:

mains surge

over-current on the output

excessive heating 

DC connect

 

of the input signal 

Any of these events may cause the amplifier to halt for a short period, limit the signal 
output, or blow the internal melt fuse. A red warning led will also light up in most of 
those cases to inform the user.
Still damage can occur if:

the amplifier is exposed to excessive input signals on the external signal socket

excessive mains voltages on the mains socket

load impedance lower than 2 Ohm on the output speakon socket

capacitive or inductive loads on the output speakon socket

adverse contact of mains power leads to the housing

Connecting a 115V amplifier to 230V will fatally damage the amplifier. 
Connecting a 230V amplifier to 115V mains will not work. 
This Qam amplifier has fixed mains settings and will not adapt outside a +- 10% range.

6. Prevent mechanical damage

Always follow the shipment instructions below for any carrier of flight shipment.
And do not expose the amplifier to:

excessive dust

shocks in excess of 25 G or a 10 cm drop or equivalent.

temperatures above 50 degrees Celsius or below -20 degrees Celsius.

This is electronic measurement equipment that requires care in handling and shipping.

7. Safety instruction

Do not expose the amplifier to water, other fluids, combustible gases. (If the 
outside of the case becomes dirty or stained, carefully wipe the surface with a 
dry cloth only.)

Do not place objects against or on top of the amplifier. 

Allow free flow of air around the amplifier.

Only use a triple line, earthed, mains cable with a standard IEC socket and with a 
cable suitable for 10 Ampere or more, and only the specified type of fuses.

Wear ear protection when the amplifier is connected to a source or loudspeaker.

8. Technical specification

Specifications*:

Frequency range with an external signal: 

20-20000 Hz 

Frequency range white and pink noise:

50-20000 Hz third octave bands

Amplification setting accuracy:

+- 0.5 dB

Maximum voltage output: 

150 Volt pk-pk

Maximum current output:

20 Ampere RMS

Maximum continuous power output:

up to 1000 Watt RMS**

Minimum load impedance: 

2 Ohm

www.qsources.be

[email protected]

Ketelwinning 38 B-3290 Diest Belgium

Copyright  Qsources BVBA

Summary of Contents for INFRA

Page 1: ...Basic operation 4 Low frequency tuning 5 Prevent electrical damage 6 Prevent mechanical damage 7 Safety instruction 8 Specifications 9 Warranty 10 Questions and Answers 11 Declaration of conformity 12...

Page 2: ...cted source and from the amplifier This may sound unnatural or distorted But it is normal and it is the undistorted low crest factor noise signal Externals signals of different nature can be used like...

Page 3: ...pressing the on off switch on the rear next to the mains socket It can take up to 8 seconds for the amplifier to activate The amplifier will initially show a set ting of zero output level and pink no...

Page 4: ...e equalization is displayed and the LED bar on the far right will point to the type of signal as printed next to the LED bar The level of output power noise will vary significantly when going from L t...

Page 5: ...d bands can be adapted F1 50 Hz 6dB 0dB 6dB F2 63 Hz 6dB 0dB 6dB F3 80 Hz 6dB 0dB 6dB F4 100 Hz 6dB 0dB 6dB F5 125 Hz 6dB 0dB 6dB F6 163 Hz 6dB 0dB 6dB F7 200 Hz 6dB 0dB 6dB F8 250 Hz 6dB 0dB 6dB F9 3...

Page 6: ...tave band up to the next band This way it is possible to scroll through the bands from F1 to F2 up till F9 After F9 it will display F0 which is not a third octave but all frequencies above 400 Hz Pres...

Page 7: ...expose the amplifier to excessive dust shocks in excess of 25 G or a 10 cm drop or equivalent temperatures above 50 degrees Celsius or below 20 degrees Celsius This is electronic measurement equipmen...

Page 8: ...to a third party or to the property of a third party This is electronic measurement equipement that requires care in handling and shipping 10 Questions and answers How long does it take the temperatur...

Page 9: ...s stuttering distorted We do crest factor optimization on noise signals which makes the random noise sound different from normal high crest factor white or pink random noise This can seem to be distor...

Page 10: ...ove mentioned product complies with the following standards EN 60065 EN 61010 1 Responsible for this declaration is the producer Qsources BVBA Ketelwinning 38 3290 Diest Belgium Declared by P J G van...

Reviews: