7
TD-000485 -01 -A
Installation
The Q-Sys TSC-7w is designed to be mounted in a wall, or podium/desk, and so on. When you are mounting the unit in a wall, there are two options,
mounting the unit during construction of the wall, or mounting into an existing wall. The following instructions cover both installation options.
General Requirements
The TSC-7w
• Must have access to the Q-LAN Ethernet.
• Must be mounted with suffi cient space for adequate ventilation.
• Should not be mounted in a location where the TSC-7w may be an obstruction, for example, in a walkway or other traffi c areas.
• Mounting surface Thickness:
• Maximum – 1 1/4” (31.5 mm),
• Minimum – 1/2” (12.7 mm)
Power Source
• PoE (Power over Ethernet – IEEE 802.3af class 3 device) LAN A only
• 12V DC AUX Power source (not supplied)
◦
12V DC @ 1A (12W)
◦
Barrel connector:
»
Negative contact – 5.5mm +/- 0.2mm
»
Positive contact – 2.5mm +/- 0.2mm
»
Length - 9.5mm +/- 0.3mm