background image

5

Introduction - Networking the RAVE 522aa

The RAVE 522aa has two RJ-45 network connection ports on the rear panel. One port is labeled "QSControl" and supports standard 
10BASE-T Ethernet.  The other port is labeled "CobraNet" and supports 100BASE-TX, also known as "Fast Ethernet". In the following 
sections, we describe the use of these ports and show example network connection schemes.

The RAVE 522aa supports two distinct kinds of network activity; the first is audio transport via CobraNet, and the second is QSCon-
trol.net. The user can choose to install one network for CobraNet traffic and a second separate network for QSControl traffic. We call 
this the "Two Wire Interface". Alternately, it is possible to run both QSControl data and audio traffic via the CobraNet port. In this case 
the QSControl port is unused. We call this the "Single Wire Interface".

Under the most demanding real-time control conditions and when using the lowest latency CobraNet settings, users may experience 
better QSControl performance using separate networks, especially when displaying a great many real-time meters. For most applica-
tions, separate networks won't provide any discernible benefits and will of course cost more. We therefore recommend using the Sin-
gle Wire Interface when running CobraNet. 

If your application uses only analog I/O without CobraNet, then you should use the QSControl port for QSControl traffic and ignore the 
CobraNet port.

Why CobraNet Needs Special Treatment:

Ordinary Ethernet traffic has no guaranteed time of delivery. Packets of information may arrive at their destination out of order and 
some may be delayed more than others. This is fine for E-mail and even for downloading MP3 files over the Internet. Everything ends up 
properly reassembled at the destination, but how long this takes will vary according to network loading, span, etc. In contrast, Cobra-
Net is "real time" - it delivers audio with a minimal, consistent transmission delay. CobraNet is designed to use as much of conventional 
networking technology as possible while providing both guaranteed time of delivery and isochronicity - maintaining a phase-locked 
sample-accurate clock across the entire network. These requirements mean that ordinary unregulated Ethernet data cannot be freely 
mixed with CobraNet information. The two can coexist on the same wire, but only by adhering to the proper rules.

To learn more about CobraNet and appropriate network topologies, please visit http://www.qscaudio.com/products/network/
resources.htm and http://www.peakaudio.com/CobraNet/background.html.

Notes on Network Systems Design:

As with any communications system, the reliability and performance of a local area network is intimately related to the designer's skill 
and knowledge in implementing a topology that is robust, efficient and standards-compliant. Proper network design is even more criti-
cal in distributed multimedia systems. Therefore, it is important for the system designer to realize that some conventional network 
practices must be avoided. Although each network design is unique and may carry its own performance requirements, compliance to 
the following three points will assist in building an audio network that is trouble free and efficient. 

First, audio and conventional data communications deliveries should not exist on the same LAN or VLAN. The exception to this is the 
RAVE 522aa Single Wire Interface, which offers a solution for converging audio and QSControl.net onto the same LAN or VLAN. How-
ever, conventional communications, such as corporate networks, print services, e-mail and Internet access, should not exist alongside 
CobraNet audio and QSControl.net on the same LAN or VLAN. Further, CobraNet audio and QSControl.net data should not exist 
together on the same LAN or VLAN when implementing the Two Wire Interface. This is not to say that conventional communications 
cannot share the same network hardware with a RAVE 522aa. In fact, common network hardware, such as managed Ethernet switches 
and media converters, can service both RAVE 522aa products and conventional data communications equipment so long as the man-
aged switch or media converter are partitioned into separate network domains. This is normally done by configuring a separate VLAN 
for each data type. (Some switches may allow individual port assignments or support partitions through DIP switch selection.)

Second, CobraNet audio must traverse either a repeater domain or a network switch domain. The point here is that the CobraNet port 
on a RAVE 522aa must connect directly to, and only to, either a repeater LAN or a switched Ethernet LAN. Hybrid networks containing 
both repeaters and switches are not permitted on the audio segment. Connecting the CobraNet port to a repeater that is in turn con-
nected to a network switch poses an illegal and non-compliant condition. We recommend always connecting the QSControl and/or 
CobraNet port(s) directly to network switch ports. 

Summary of Contents for RAVE 522aa

Page 1: ...TD 000164 00 rev B TD 000164 00 RAVE 522aa 8x8 CobraNet Enabled Signal Processor Hardware Manual...

Page 2: ...ord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE S...

Page 3: ...blets etc all at the same time from anywhere a connection to the QSControl network is available The QSControl network can also be managed from a single computer running both the client and the server...

Page 4: ...ere We ve applied our many years experience in supporting high end installed sound with our previous system building products such as RAVE QSControl CM16a DSP 3 DSP 4 and DSP 30 The RAVE 522aa brings...

Page 5: ...rules To learn more about CobraNet and appropriate network topologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background html Notes on Ne...

Page 6: ...a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl net segment does not requ...

Page 7: ...without a network switch However you would have to physically connect your computer first to one unit and then to the other With this elementary connection you don t have a true network It is like mak...

Page 8: ...guration works well when CobraNet audio deliveries are point to point Though the example shows only two RAVE BASIS units as many devices may be connected as there are available switch ports All units...

Page 9: ...te VLAN for QSControl net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for QSControl including the system controller and a second...

Page 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Page 11: ...pment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mounting Rack moun...

Page 12: ...m is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Panel features be disabled Display hard drive system standb...

Page 13: ...ontroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the RAVE 522aa to sy...

Page 14: ...he input signal terminal block connectors into the input recep tacles Connection pin out is printed on the rear label for reference Refer to the illustrations for balanced and unbal anced connections...

Page 15: ...stop bit and flow control Xon Xoff LED Indicators When the RAVE 522aa is plugged into a properly functioning AC outlet it will power up and briefly display a welcome screen on the LCD dis play POWER...

Page 16: ...the control and accepting choices entering by pushing in on the control The accessible menus and sub menus may appear differently than the example shown Software updates may occasionally improve the i...

Page 17: ...lt Boot Screen Right side buttons serve as up down navigation Arrow characters indi cate right side button context If additional menus are available the arrow character will be shown Main Menu Screens...

Page 18: ...lient Server selection keep both Client and Server selected This will be appropriate for general use 8 When prompted Select Installation Folder specify the installation directory or accept the default...

Page 19: ...nnections verify IP addresses are set correctly ver ify Subnet masks are set correctly and verify AC power is properly applied to the RAVE 19 Click on the RAVE 522aa in the inventory root A view of ap...

Page 20: ...sed will be copies of other channels CobraNet Channel Resolution All CobraNet audio will be processed internally within RAVE 522aa at 24 bit resolution The RAVE 522aa may receive any valid resolu tion...

Page 21: ...icate with the RAVE 522aa if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port in...

Page 22: ...click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the lette...

Page 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the RAVE 522aa you want to communicate with in the text box and cli...

Page 24: ...lay Standard CobraNet Latency Low Latency RAVE to Network Analog input through full DSP chain to CobraNet output 7 104 milliseconds 4 438 milliseconds Network to RAVE CobraNet input through full DSP c...

Page 25: ...a Euro Style detachable terminal blocks Configuration Single ended ground referenced Pinout 1 Signal 2 CHASSIS GND Normal Operating Range Reads signals between 0 5V nominally Potentiometer Operation...

Page 26: ...ts suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products wi...

Reviews: