background image

2

EXPLANATION OF TERMS AND SYMBOLS

The term “

WARNING

” indicates instructions regarding personal safety. Failure to follow them may result in bodily injury or death.

The term “

CAUTION

” indicates instructions regarding possible damage to physical equipment. Failure to follow them may result in 

equipment damage to equipment that may not be covered under the warranty.

The term “

IMPORTANT

” indicates instructions or information that are vital to the successful completion of the procedure.

The term “

NOTE

” indicates additional useful information.

The lightning flash with arrowhead symbol in a triangle alerts the user to the presence of uninsulated dangerous voltage within the 
product’s enclosure that may constitute a risk of electric shock to humans. 

The exclamation point within a triangle alerts the user to important safety, operating, and maintenance instructions in this manual.

IMPORTANT SAFETY INSTRUCTIONS

    WARNING!

: TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.

• 

Elevated Operating Ambient

 – If installed in a closed or multi-unit rack assembly, the ambient operating temperature 

of the rack environment may be greater than room ambient. Consideration should be given to ensure that the maximum 
operating temperature range (0°C to 50°C (32°F to 122°F ) is not exceeded. However, if installing a GP8x8 in a multi-unit 
rack assembly with units on all sides, the maximum operating temperature should not exceed 40°C when devices are placed 
above or below.

• 

Reduced Air Flow

 – Installation of the equipment in a rack should be such that the amount of air flow required for safe 

operation of the equipment is not compromised.

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Do not submerge the apparatus in water or liquids. 
7.  Do not use any aerosol spray, cleaner, disinfectant or fumigant on, near or into the apparatus. 
8.  Clean only with a dry cloth.
9.  Do not block any ventilation opening. Install in accordance with the manufacturer’s instructions.
10. Keep all ventilation openings free of dust or other matter.
11. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
12. Do not unplug the unit by pulling on the cord, use the plug.
13. Only use attachments/accessories specified by the manufacturer.
14. Unplug this apparatus during lightning storms or when unused for long periods of time.
15. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as 

liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate 
normally, or has been dropped.

16. Adhere to all applicable, local codes.
17. Consult a licensed, professional engineer when any doubt or questions arise regarding a physical equipment installation.

Summary of Contents for Q-SYS QIO Series

Page 1: ...Hardware User Manual QIO Series Network Audio I O Expanders QIO ML4i QIO L4o QIO ML2x2 QIO Series Network Control I O Expanders QIO GP8x8 QIO S4 QIO IR1x4 TD 001667 01 D TD 001667 01...

Page 2: ...on all sides the maximum operating temperature should not exceed 40 C when devices are placed above or below Reduced Air Flow Installation of the equipment in a rack should be such that the amount of...

Page 3: ...ction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to...

Page 4: ...ng bracket 4x Foam spacer 4x M4 x 6 mm pan head screws 1x Warranty statement 1x Safety and regulatory statements QIO L4o 1x QIO L4o 4x Line Out connector green 2x Power connector black 2x Surface moun...

Page 5: ...mounting bracket 4x Foam spacer 4x M4 x 6 mm pan head screws 1x Warranty statement 1x Safety and regulatory statements QIO GP8x8 1x QIO GP8x8 2x GPIO connector black 2x Power connector black 2x Surfac...

Page 6: ...4 x 6 mm pan head screws 1x Warranty statement 1x Safety and regulatory statements QIO IR1x4 1x QIO IR1x4 1x IR Output connector black 1x IR Input connector black 2x Power connector black 2x Surface m...

Page 7: ...locates the right amount of analog audio connectivity in desired locations without bulk or waste Up to four devices may be daisy chained off one access switch port provided 24 VDC power is available...

Page 8: ...tective earth when using class I power supply Power over Ethernet PoE NOTE A device cannot provide daisy chained power to an external device with Power over Ethernet An external 24 VDC supply is requi...

Page 9: ...wer Input 24 VDC 2 5 A Auxiliary power 24 VDC 2 5 A 2 pin Euro connector 2 Daisy Chain Power Output 24 VDC 2 5 A Auxiliary power 24 VDC 2 5 A 2 pin Euro connector 3 LAN PoE RJ 45 connector 802 3af PoE...

Page 10: ...nput 24V DC 2 5 A Auxiliary power 24 VDC 2 5 A 2 pin Euro connector 2 Daisy Chain Power Output 24V DC 2 5 A Auxiliary power 24 VDC 2 5 A 2 pin Euro connector 3 LAN PoE RJ 45 connector 802 3af PoE Type...

Page 11: ...r 24 VDC 2 5 A 2 pin Euro connector 2 Daisy Chain Power Output 24V DC 2 5 A Auxiliary power 24 VDC 2 5 A 2 pin Euro connector 3 LAN PoE RJ 45 connector 802 3af PoE Type 1 Class 3 power Q LAN 4 LAN THR...

Page 12: ...connector Ethernet daisy chaining 5 Device Reset Use a paperclip or similar tool to restore default network settings and recover factory default settings Before attempting a reset refer to the Q SYS H...

Page 13: ...ary power 24 VDC 2 5 A 2 pin Euro connector 3 LAN PoE RJ 45 connector 802 3af PoE Type 1 Class 1 power Q LAN 4 LAN THRU RJ 45 connector Ethernet daisy chaining 5 Device Reset Use a paperclip or simila...

Page 14: ...ground TX Output Transmit data RX Input Receive data RTS Output Ready to Send1 CTS Input Clear to Send1 1 When using hardware flow control RS485 Half Duplex TX or RX Pinout COM 1 Configurable Pin Sign...

Page 15: ...DC 2 5 A Auxiliary power 24 VDC 2 5 A 2 pin Euro connector 3 LAN PoE RJ 45 connector 802 3af PoE Type 1 Class 1 power Q LAN 4 LAN THRU RJ 45 connector Ethernet daisy chaining 5 Device Reset Use a pape...

Page 16: ...put provides 3 3VDC and receives IR data IR Output 1 4 IR Mode Pinout Pin Signal Flow Description SIG Output IR transmit data N A Signal reference IR Output 1 4 Serial RS232 Mode Pinout Pin Signal Flo...

Page 17: ...g Clips For each QIO Endpoint you are installing in the tray insert and attach a retaining clip in either the short or long length location using a flat head screw Short Length Long Length Attach the...

Page 18: ...d pan head screws included with the QIO Endpoint ship kit The brackets are symmetrical to accommodate mounting right side up to a ground facing surface NOTE Fasteners for attaching the bracket to a su...

Page 19: ...Support and Customer Care including their phone numbers and hours of operation qsys com contact us Warranty For a copy of the QSC Limited Warranty go to qsys com support warranty statement 2023 QSC LL...

Reviews: