SIG (Signal) Indicator LED

The green SIG (signal) indicator alerts the user to the presence of an input signal to the MD 
loudspeaker.

Normal Indication

The green SIG indicator illuminates when the input signal exceeds -25 dB.

If No Indication

Check Gain settings and increase gain if necessary. Check input connections and audio source 
for signal. If the red LIM LED illuminates, refer to the LIM indicator section, below. 

Abnormal Indication

If the green SIG LED illuminates with no signal input, there may be system oscillations or some 
other malfunction. Disconnect the input or fully reduce the gain. If the green SIG LED remains 
on, the amp may need servicing. 

LIM (Limiter) Indicator LED

The red LIM indicator alerts the user to several abnormal conditions within the MD loud-
speaker:

Continuous Bright Red Light

• Indicates protective mute mode. 
• The speaker normally passes through muting for several seconds after applying power, after 

which the light should go out, and sound should be heard. 

• If the speaker enters Mute during operation, it has either overheated or developed a fault. 
• Overheating should correct itself within 1-2 minutes, after which sound should resume. See 

below for a full explanation of thermal protection. 

• Short periods of muting indicate a component fault. In this case AC power should be removed 

and the speaker serviced. 

Momentary Bright Red Flashes

• During operation, bright flashing indicates clipping (overdrive distortion). 
• This is normally due to excessive volume, and will likely be accompanied by audible distortion. 
• If the speaker mutes repeatedly during peaks, there may be a component fault. AC power should 

be removed and the speaker serviced. 

Continuous Half-bright Light

• Indicates that the internal limiter is reducing gain, due to prolonged clipping and/or excessive 

temperature. 

• After several seconds of severe clipping, the limiter will reduce power to protect the speaker 

and improve the sound. This results in a steady, half-bright red indication. Any further clipping 
will still result in bright flashes on top of the steady half-bright indication. When the program 
level is reduced, the limiter will clear after several seconds, and the red indicator will go out. 

• If the power module overheats, the first response is to trigger limiting, to reduce volume and 

limit further temperature rise. This results in a steady half-bright illumination that does not clear 
even after reducing program level. It may take several minutes for temperature to drop and clear 
the limiter. During this time, the exposed heat sink will feel uncomfortably hot to the touch. If 
overheating continues, the amplifier will ultimately mute, resulting in a full-bright red indication. 
When muting clears, the amplifier will resume operation, with thermal limiting still active until 
it further cools off. 

• Overheating is usually caused by excessive ambient temperature, since the internal temperature 

rise of the Class-D power module is relatively low. Protect the speaker from excessive tempera-
tures, such as being placed over a heater vent, or allowing direct sunlight to impinge upon the 
heat sink surface.

LIM (limiter) 
indicator LED

SIG (signal) 
indicator LED

Summary of Contents for MD-FP122/64r

Page 1: ...ser Manual MD FP122 64r 60 x40 HxV 12 inch two way MD FP122 66 60 x 60 12 inch two way MD FP122 94r 90 x40 12 inch two way MD FP122 96r 90 x 60 12 inch two way MD FP122 124r 120 x40 12 inch two way MD...

Page 2: ...ducts Inc 13 Unplug the apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has bee...

Page 3: ...connectors 9 Serial Number Plate 5 Handles only on black enclosures 10 Power Switch AC Mains Switch NOTE Handles are provided on black colored enclosures only White colored enclosures are not equipped...

Page 4: ...gned properly Insert the connector fully and rotate clockwise until the locking mechanism engages The correct AC line voltage is shown on the serial number label on the rear panel Connecting to the wr...

Page 5: ...l clockwise to increase gain and counter clockwise to decrease gain The attenuation in dB from maximum is shown on the label The Gain control is marked in dB of attenuation There are 21 detents for re...

Page 6: ...volume and will likely be accompanied by audible distortion If the speaker mutes repeatedly during peaks there may be a component fault AC power should be removed and the speaker serviced Continuous...

Page 7: ...forged shoulder eye bolts QSC part number SR 000096 00 Contact QSC Technical Services department for complete information Before placing installing rigging or suspending any speaker product inspect a...

Page 8: ...riately load rated parts Shock Loading When a load is either moved or stopped its static weight is magnified Sudden movements can magnify the static weight several times This magnification of static w...

Page 9: ...ving an assistant hold the grill from springing free Remove the four screws from the other side of the grill Place the grill and retaining screws aside 2 Remove the eight horn retaining screws Careful...

Page 10: ...uirements Pink noise 6 dB crest factor Idle 0 5 A 100 BTU waste heat 1 8 power 2 5 A 570 BTU waste heat 1 3 power 5 0 A 1380 BTU waste heat full power 15 0 A 4010 BTU waste heat Typical program materi...

Page 11: ...crest factor Idle 0 5 A 100 BTU waste heat 1 8 power 2 5 A 570 BTU waste heat 1 3 power 5 0 A 1380 BTU waste heat full power 15 0 A 4010 BTU waste heat Typical program material at full power 2 5 A 570...

Page 12: ...12 Dimensions NOTE Handles are provided on black colored enclosures only White colored enclosures are not equipped with handles...

Page 13: ...ci dental and or consequential damages This warranty gives you specific legal rights This limited warranty is freely transferable during the term of the warranty period Customer may have additional ri...

Reviews: