background image

1675 MacArthur Blvd., Costa Mesa, CA, 92626 USA
Main Number (714) 754-6175 or toll free (USA only) (800) 854-4079
Customer Service(714) 957-7150 or toll free (USA only) (800) 772-2834

MD Series Powered Loudspeaker Products

User Manual    

MD-FP122/64r

 

  

60° x40° (HxV)

12-inch, two-way

MD-FP122/66

60° x 60°

12-inch, two-way

MD-FP122/94r

90° x40°

12-inch, two-way

MD-FP122/96r

90° x 60°

12-inch, two-way

MD-FP122/124r

120° x40°

12-inch, two-way

MD-FP152/64r

60° x40°

15-inch, two-way

MD-FP152/66

60° x 60°

15-inch, two-way

MD-FP152/94r

90° x40°

15-inch, two-way

MD-FP152/96r

90° x 60°

15-inch, two-way

MD-FP152/124r

120° x40°

15-inch, two-way

*TD-000186-00*

TD-000186-00-D 

Summary of Contents for MD-FP122/64r

Page 1: ...ser Manual MD FP122 64r 60 x40 HxV 12 inch two way MD FP122 66 60 x 60 12 inch two way MD FP122 94r 90 x40 12 inch two way MD FP122 96r 90 x 60 12 inch two way MD FP122 124r 120 x40 12 inch two way MD...

Page 2: ...ducts Inc 13 Unplug the apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has bee...

Page 3: ...connectors 9 Serial Number Plate 5 Handles only on black enclosures 10 Power Switch AC Mains Switch NOTE Handles are provided on black colored enclosures only White colored enclosures are not equipped...

Page 4: ...gned properly Insert the connector fully and rotate clockwise until the locking mechanism engages The correct AC line voltage is shown on the serial number label on the rear panel Connecting to the wr...

Page 5: ...l clockwise to increase gain and counter clockwise to decrease gain The attenuation in dB from maximum is shown on the label The Gain control is marked in dB of attenuation There are 21 detents for re...

Page 6: ...volume and will likely be accompanied by audible distortion If the speaker mutes repeatedly during peaks there may be a component fault AC power should be removed and the speaker serviced Continuous...

Page 7: ...forged shoulder eye bolts QSC part number SR 000096 00 Contact QSC Technical Services department for complete information Before placing installing rigging or suspending any speaker product inspect a...

Page 8: ...riately load rated parts Shock Loading When a load is either moved or stopped its static weight is magnified Sudden movements can magnify the static weight several times This magnification of static w...

Page 9: ...ving an assistant hold the grill from springing free Remove the four screws from the other side of the grill Place the grill and retaining screws aside 2 Remove the eight horn retaining screws Careful...

Page 10: ...uirements Pink noise 6 dB crest factor Idle 0 5 A 100 BTU waste heat 1 8 power 2 5 A 570 BTU waste heat 1 3 power 5 0 A 1380 BTU waste heat full power 15 0 A 4010 BTU waste heat Typical program materi...

Page 11: ...crest factor Idle 0 5 A 100 BTU waste heat 1 8 power 2 5 A 570 BTU waste heat 1 3 power 5 0 A 1380 BTU waste heat full power 15 0 A 4010 BTU waste heat Typical program material at full power 2 5 A 570...

Page 12: ...12 Dimensions NOTE Handles are provided on black colored enclosures only White colored enclosures are not equipped with handles...

Page 13: ...ci dental and or consequential damages This warranty gives you specific legal rights This limited warranty is freely transferable during the term of the warranty period Customer may have additional ri...