Specifications

MD-FP122/64r       MD-FP122/66          MD-FP122/94           MD-FP122/96r         MD-FP122/124r

Frequency Response, -6dB

55 Hz - 17.5 kHz

       55 Hz - 17.5 kHz               55 Hz - 19.5 kHz               55 Hz - 16.5 kHz                 55 Hz - 19 kHz

Frequency Range, -10dB

50 Hz - 18 kHz

       50 Hz - 19.5 kHz               50 Hz - 20 kHz                  50 Hz - 19.5 kHz                 50 Hz - 20 kHz

Maximum Output 

129 dB continuous        127 dB continuous           128 dB continuous          127 dB continuous             126 dB continuous
139 dB peak

       137 dB peak

               138 dB peak                     135 dB peak                       137 dB peak

Nominal coverage, H x V

60°x40° rotatable        60°x60°                            90°x40° rotatable           90°x60° rotatable              120°x40° rotatable  

    

(as installed at factory)

Directivity Index

12.8

       11.7

               11.3

                       10.2                                   9.6

Directivity Factor

19.0

       14.7

               13.4

                       10.5                                  9.1

Acoustic Crossover Freq.

1.4k Hz

       1.2k Hz

              1.4k Hz

                      1.2k Hz                               1.2k Hz

Transducer Description

LF: 12” (305mm) diameter, 4” (102mm) voice coil, ferrite magnet
HF: 1.4” (36mm) exit diameter, 2.5” (64mm) voice coil, neodymium magnet, all models

Amp Power

LF: 800W, HF: 200W, all models

Input Sensitivity

1.2V

rms 

 (+4 dBu), all models

Input Headroom/Clipping

7.5V

rms 

 (+19.5 dBu), all models

Input Connector/Impedance

XLR female, 20k ohm, balanced, all models (pin 1:Earth, Pin 2: +, Pin 3: -)

Output Connector

XLR male, wired in parallel with Input connector

Controls, Indicators, and

Rotatable horn assembly,

 

Gain control, 100 Hz high-pass filter switch, Clip/Limit (red LED), Signal presence (green

Adjustments

LED), AC Power (blue LED), all models

Protection, Agency certs.

Thermal limiting, On/Off muting, AC in-rush current limiting, FCC class B (conducted and radiated), UL/CE listed

Operating Voltages

Available in 120V or 230V versions (+15%, -40%)

AC Power Requirements

Pink noise (6 dB crest factor) - Idle <0.5 A (<100 BTU waste heat) / 1/8 power 2.5 A (570 BTU waste heat) / 1/3 power 
5.0 A (1380 BTU waste heat), full power 15.0 A (4010 BTU waste heat)

Typical program material at full power- 2.5 A (570 BTU waste heat)

AC Power Connector

Factory supplied cordset:  Neutrik Powercon on 10’ (3m) #18AWG 120V North American cordset

Dimensions

20.5” (521mm) W, 35.0” (889mm) H, 17.1” (432mm) D, including rear heatsink fins 
Allow for 100mm (4.0”) of free space behind the enclosure to assure proper amplifier cooling

Weight

88 lb/40 kg, all models

Finish and Grill

All models- wear resistant textured paint finish with powder-coated perforated steel grill

Notes:

1- Maximum Peak SPL: Calculated by adding the loudspeaker’s sensitivity (1W at 1m) to the peak power (dBw) of the amplifier provided.
2- Coverage: Included angle between -6dB points, plus X, minus Y dB, 500 to 3.2k Hz, taken at ISO preferred one-third octave intervals, or for an otherwise specified frequency range.
3- Directivity Index (DI): Difference between on-axis SPL and average SPL (considering all axes) for the specified coverage range. DI= 10 log Q
4- Directivity Factor (Q): Directivity index expressed as a power ratio Q=10 exp DI/10
5- Amplifier Power: The maximum sustained power at less than 1% clipping, averaged over the intended frequency range,
6- Input Sensitivity: The sine-wave input voltage required to reach amplifier clipping, measured within the frequency range used to determine Maximum Peak SPL, with the gain on “normal” and no gain reduction 

due to limiting.

7- Input Headroom/Clipping: Maximum input voltage.
8- Input Connector/Impedance: RF shunt capacitance should not reduce impedance by more than 30% at 20k Hz.
9- TBD= to be determined, data not available at time of printing

Summary of Contents for MD-FP122/64r, MD-FP122/94r, MD-FP122/124r, MD-FP152/94r, MD-FP152/64r,...

Page 1: ...ser Manual MD FP122 64r 60 x40 HxV 12 inch two way MD FP122 66 60 x 60 12 inch two way MD FP122 94r 90 x40 12 inch two way MD FP122 96r 90 x 60 12 inch two way MD FP122 124r 120 x40 12 inch two way MD...

Page 2: ...ducts Inc 13 Unplug the apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has bee...

Page 3: ...connectors 9 Serial Number Plate 5 Handles only on black enclosures 10 Power Switch AC Mains Switch NOTE Handles are provided on black colored enclosures only White colored enclosures are not equipped...

Page 4: ...gned properly Insert the connector fully and rotate clockwise until the locking mechanism engages The correct AC line voltage is shown on the serial number label on the rear panel Connecting to the wr...

Page 5: ...l clockwise to increase gain and counter clockwise to decrease gain The attenuation in dB from maximum is shown on the label The Gain control is marked in dB of attenuation There are 21 detents for re...

Page 6: ...volume and will likely be accompanied by audible distortion If the speaker mutes repeatedly during peaks there may be a component fault AC power should be removed and the speaker serviced Continuous...

Page 7: ...forged shoulder eye bolts QSC part number SR 000096 00 Contact QSC Technical Services department for complete information Before placing installing rigging or suspending any speaker product inspect a...

Page 8: ...riately load rated parts Shock Loading When a load is either moved or stopped its static weight is magnified Sudden movements can magnify the static weight several times This magnification of static w...

Page 9: ...ving an assistant hold the grill from springing free Remove the four screws from the other side of the grill Place the grill and retaining screws aside 2 Remove the eight horn retaining screws Careful...

Page 10: ...uirements Pink noise 6 dB crest factor Idle 0 5 A 100 BTU waste heat 1 8 power 2 5 A 570 BTU waste heat 1 3 power 5 0 A 1380 BTU waste heat full power 15 0 A 4010 BTU waste heat Typical program materi...

Page 11: ...crest factor Idle 0 5 A 100 BTU waste heat 1 8 power 2 5 A 570 BTU waste heat 1 3 power 5 0 A 1380 BTU waste heat full power 15 0 A 4010 BTU waste heat Typical program material at full power 2 5 A 570...

Page 12: ...12 Dimensions NOTE Handles are provided on black colored enclosures only White colored enclosures are not equipped with handles...

Page 13: ...ci dental and or consequential damages This warranty gives you specific legal rights This limited warranty is freely transferable during the term of the warranty period Customer may have additional ri...

Reviews: