24
QSC, LLC
6.2 AMP/PSU board
Removal
1. Follow the
removal
2. Adjust the amplifier module so that the front panel is face down on the work bench.
3. Cut and remove 2 zip ties that secure the ribbon cable to the metal cover. See Figure 6.2.1.
4. Disconnect the 3 ribbon connectors (LED, AMP/PSU, and Fan) from the input/DSP board as shown in Figure 6.2.2. The
ribbon cables going to the LCD board can remained connected.
6. Remove the 3 machine screws as shown in Figure 6.2.5.
7. Lift up and rotate the metal cover assembly (which includes the fan and output
connector PCB) to provide access to the AMP/PSU board. See Figure 6.2.6 for
a visual aide.
Troubleshooting tip
: Leave the cover up in this position while connected to AC
power/outputting audio to aide in troubleshooting components on the top-
side of the AMP/PSU board.
8. Disconnect the AC wiring harness from AMP/PSU board by putting pressure on
the locking tab and lifting the wiring harness up. See Figure 6.2.4.
9. Remove the 2 machine screws that secure the output connector PCB to the
metal cover. Set the metal cover assembly aside.
10. Remove the 7 short machine screws that secure the PCB to the heatsink
Figure 6.2.1 - Zip ties for ribbon
Figure 6.2.2 - Ribbon connectors.
Figure 6.2.3 - Folding AMP/PSU ribbon.
Figure 6.2.4 - AC wiring harness
Figure 6.2.5 - Metal cover removal/installation steps
Figure 6.2.6 - Metal cover rotated up for AMP/PSU access