background image

 

 

 

 

 

 

TD-000449-00-A

Connections

Inputs (Channels 1 & 2)      

Input Impedance: 40 k

Ω

 Balanced, 20 k

Ω

 Unbalanced

 

(Figure 2

)

 See 

Table 1

 for wiring   

1. XLR female

2.  ¼" female TRS Phone Jack

3.  USB Standard B connector - Used for updating the amplifi er fi rmware.

Outputs (Channels A & B)  

4

Ω

 or 8

Ω

 impedance 

(Figure 3)

1.  NL4 – Do not combine the audio outputs in any way. Do not connect the audio outputs to ground.

AC Power

A.  Connect the IEC power cord to the AC receptacle on the rear of the amplifi er. 

(Figure 4)

 

Controls  

See

 

Figure 5

1.  Channel A clip indicator

2.  Channel A signal presence indicator

3.  Power Switch/LED on/off

4.  Adjust Channel A gain

5.  Home – go to Home screen / view Preset screen

6.  Enter – select highlighted item and/or confi rm parameter change

7.  Exit – return to previous screen and/or undo parameter changel

8.  Adjust Channel B gain, select and adjust controls

9.  Channel B signal presence indicator

10. Channel B clip indicator

— Figure 6 — 

Clip
LED

Clip
LED

Signal

Presence

Routing

Matrix

4-band

PEQ

Delay

Limiter

Meter

Gain

High-pass

Filter

Polarity

Low-pass

Filter

D/A

Converter

B

A/D

Converter

Signal

Presence

4-band

PEQ

Delay

Limiter

Meter

Gain

High-pass

Filter

Polarity

Low-pass

Filter

D/A

Converter

Crossover

Digital Signal Processing

Shown on

LCD

Front
Panel

Knobs

Front
Panel

LEDs

Front Panel

LEDs

Front Panel

LEDs

Controlled

by Preset
Selection

A

A/D

Converter

Sensitivity

Sensitivity

GXD Amplifier Signal Flow

Switched

in DSP

— Figure 2 — 

1

2

3

POS

NEG

GROUND

XLR

2

3

1

1/4

TIP

RING

SLEEVE

— Table 1 —  

— Figure 3 — 

LOCK

OUTPUTS TO SPEAKERS

CH A

1+ 1-

CH B

2+ 2-

CH B

1+ 1-

LOCK

— Figure 4 — 

— Figure 5 — 

HOME

ENTER

EXIT

+

STATUS: OK

3

4

5

6

7

8

GAIN

P1: ST SAT FULL RANGE

A

B

-100

10.0

1

2

9

10

CLIP
SIG

A

PROCESSING

AMPLIFIER

dB

GAIN/DSP CONTROL

CLIP

SIG

B

Summary of Contents for GXD Series

Page 1: ...information The intent of the lightning flash with arrowhead symbol in a triangle is to alert the user to the presence of un insulated dangerous voltage within the product s enclosure that may be of s...

Page 2: ...or undo parameter changel 8 Adjust Channel B gain select and adjust controls 9 Channel B signal presence indicator 10 Channel B clip indicator Figure 6 Clip LED Clip LED Signal Presence Routing Matri...

Page 3: ...10 dB 6 Amplifier Status Configurations There are four basic types of configuration 2 channels in stereo DSP 2 channels out P1 through P7 Figure 31 2 channels in separate DSP 2 channels out P8 throug...

Page 4: ...Save As ENTER 4 B Location ENTER 5 B the Location p1 to p20 ENTER 6 B Name ENTER 7 B letter number hyphen or space ENTER repeat When finished EXIT 8 B Save ENTER ENTER Stereo DSP Digital Signal Proces...

Page 5: ...2 B STEREO DSP press ENTER 3 B Delay ENTER 4 B Delay 0 00 to 56 30 ft or 17 16 m or 50 ms ENTER HOME Limiter See Figure 22 1 From Home ENTER 2 B STEREO DSP ENTER 3 B Limiter ENTER 4 B Type ENTER 5 B M...

Page 6: ...cessing or Lock All ENTER HOME Reset 1 From Home ENTER 2 B Utilities ENTER 3 B Reset ENTER 4 B Factory Reset ENTER ENTER Figure 27 UTILITIES STATUS AMP TOTAL RUN TIME 12 42 5 HRS HARDWARE V3 FIRMWARE...

Page 7: ...oducts website at www qsc com or contact Customer Service 1 714 957 7150 or toll free USA only 800 772 2834 to receive a copy by mail Si desea obtener una copia completa del manual del usuario de la G...