Operation

 QSControl Port

The QSControl port operates on a 10BaseT Ethernet network. This port is one of the primary means for connecting QSControl.net to the 
BASIS. The port may connect directly to a PC's 10BaseT or 10/100 (auto-sensing or auto-negotiating) network interface card using a 
crossover cable. Data from the QSControl port may also pass through network repeaters, network switches and routers. We strongly 
recommend the use of network switches to facilitate higher bandwidth and dedicated connections. 

CobraNet Port

The CobraNet port operates on a dedicated 100BaseTx (Fast Ethernet) network. The CobraNet port may connect directly to a PC's 
100BaseTx or 10/100 (auto-sensing or auto-negotiating) network interface card using a crossover cable for the purposes of configura-
tion when the BASIS 902zz is in the single-wire interface mode. During normal operation (passing audio) the CobraNet port must con-
nect to a 100BaseTx or 10/100 or 10/100/1000 (auto-sensing or auto-negotiating) switch port. Optionally, the BASIS 902zz may connect 
to another CobraNet port using a crossover cable. When the BASIS 902zz is operating in the two-wire interface mode (described in fol-
lowing sections), the CobraNet port may be connected to a network repeater. Regardless of the interface mode, all CobraNet audio data 
must pass through only network switches or only network repeaters. Combinations of these devices will cause unreliable operation and 
are not supported. Likewise, the use of routers, gateways and ATM devices are not supported for the CobraNet audio path. 

CobraNet Channel Density

The BASIS 902zz will support the acquisition of up to 32 channels via up to 4 inbound bundles (from the network). Of these 32 channels, 
any 24 may be selected to forward to the signal processing chain (DSP engine). 
The BASIS 902zz will support the delivery of up to 32 channels via up to 4 outbound bundles (to the network). Of these 32 channels, up 
to 24 may be unique (processed individually... or the result of mixed signals from the DSP engine). The remaining 8 channels (if used) 
will be copies of other channels. 

CobraNet Channel Resolution

All CobraNet audio will be processed internally within BASIS 902zz at 24-bit resolution. The BASIS 902zz may receive any valid resolu-
tion off of the network. This is currently 16-bit, 20-bit and 24-bit. Audio via inbound bundles may be in any combination of these resolu-
tions and the BASIS will process the data accordingly. All DACs will process 24-bit audio, though the least significant bits may be zero 
filled if the inbound audio format is less than 24-bit resolution. 
The BASIS 902zz will support outbound (sourced onto the network) resolutions of 16-bit, 20-bit and 24-bit. The default outbound resolu-
tion is 20-bit.

CobraNet Terms and Conditions 

Single-wire interface

 offers the best efficiency and ease of network configuration for most applications. The single-wire interface 

requires fewer network ports and less cabling. Single-wire interface refers to CobraNet audio, CobraNet control and monitoring and 
QSControl.net control and monitoring using the same network connection. This mode uses the CobraNet connection to provide all data 
communications to the BASIS product. In this mode, the port must connect to a 100BaseTx or 10/100 or 10/100/1000 (auto-sensing or 
auto-negotiating) link partner. Network repeaters will not be supported and all audio must pass through network switches only. A 
QSControl Venue Manager PC may connect to the network via a repeater or router.

Two-wire or dual-wire interface

 offers the greatest versatility in network design. Separate connections allow discrete networks 

and offer support for WAN topologies on the QSControl.net-side. Two-wire or dual-wire interface refers to CobraNet audio having a 
dedicated network link and QSControl control and monitoring having a dedicated network link. In this mode, the two ports (CobraNet 
and QSControl) must be connected to separate networks. By separate networks, we mean either physically separate hardware or the 
use of common hardware with partitioned or segmented network domains such as the use of VLANs, domain bubbles or separate port 
clusters. The dual-wire interface may support dissimilar network hardware for the two port connections (see rules above for CobraNet 
and QSControl port connections).

Summary of Contents for BASIS 902zz

Page 1: ...TD 000146 00 rev A BASIS 902zz 8 Output CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual TD 000146 00 ...

Page 2: ... cord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER OR BIRTH DEFECTS THE NON RECHARGE ABLE LITHIUM BATTERY CONTAINED IN THIS EQUIPMENT MAY EXPLODE IF IT IS EXPOSED TO FIRE OR EXTREME HEAT DO NOT SHORT CIRCUIT THE BA...

Page 3: ...ling the overall BASIS QSControl system However the BASIS 902zz also offers a front panel interface for accessing critical functions A single QSControl server computer can support several cli ents running QSC s latest Venue Manager software Thus the sound system can be operated via several computers roaming wireless laptops tablets etc all at the same time from anywhere a connection to the QSContr...

Page 4: ...net are available at www qscontrol net We invite you to visit us there We ve applied our many years experience in supporting high end installed sound with our previous system building products such as RAVE QSControl CM16a DSP 3 DSP 4 and DSP 30 The BASIS 902zz brings all that technology together in one compact powerful easy to use system We are confident that your new BASIS 902zz will provide year...

Page 5: ...pologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background html Notes on Network Systems Design As with any communications system the reliability and performance of a local area network is intimately related to the designer s skill and knowledge in implementing a topology that is robust efficient and standards compliant Proper network ...

Page 6: ...CP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl net segment does not require a single topology data path and therefore repeaters switches and routers may be assembled on the LAN in a hybrid fashion To learn more about network design rules and system compliance visit the QSC ne...

Page 7: ...However you would have to physically connect your computer first to one BASIS box and then to the other With this elementary connection you don t have a true network It is like mak ing RS 232 connections except that performance is better All the other examples are of proper networks and all require a network switch On a proper network you have direct access to all units all of the time without hav...

Page 8: ...his configuration works well when CobraNet audio deliveries are point to point Though the example shows only two units as many devices may be connected as there are available switch ports All BASIS RAVE units will be able to communicate simultaneously with the computer All will have access to CobraNet audio Switches can be con nected to other switches to build larger networks all of the normal net...

Page 9: ...VLAN for QSControl net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for QSControl including the system controller and a second dedicated network for CobraNet audio As with the previous example as many BASIS RAVE units may be connected as there are switch ports avail able All units will be able to communicate with the computer A...

Page 10: ...with its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network hardware The figure shows a separate net work switch for QSControl net traffic and a separate network switch for CobraNet audio traffic All of the previous comments regarding network expansion still ...

Page 11: ...or out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mounting Rack mount the BASIS 902zz by supporting it from underneath while aligning the mounting holes with the threaded screw holes in the rails install all four mounting screws and washers and tighte...

Page 12: ... used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Panel features be disabled Display hard drive system standby and hibernation settings should be set to Never This avoids waiting for the system to wake up if adjustment is needed after an elapsed period of time To Install QSControl net 1 Start your computer and s...

Page 13: ...ontroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the BASIS 902zz to synchronize with its internal clock If CobraNet network connection is re established the audio will mute again while the BASIS 902zz synchronizes with CobraNet Configuration Memories The BASIS 902zz ha...

Page 14: ...vel and 0 5 VDC input The contact closure and logic devices accommodate on off or state change events the variable resistor input provides full 8 bit resolution allowing for incremental change events Refer to the illustrations for connection recommendations NOTE 48 volts is the absolute maximum that can be applied to the pin without damage Voltage is with respect to chassis or the pin Logic Out Th...

Page 15: ...udio and amplifier status monitoring This can be four 2 channel amplifiers or one 8 channel amplifier or other suitable combinations If connecting a multi DataPort amplifier ensure all the DataPorts of the amplifier are con nected and that they are all connected to the same BASIS To connect the cable orient the connector properly then push into the receptacle until it is firmly seated tighten the ...

Page 16: ...e display are used to navigate through the menus The rotary select accept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting choices entering by pushing in on the control The accessible menus and sub menus may appear differently than the example shown Software updates may occasionally improve the interface On the following page is a...

Page 17: ...ult Boot Screen Right side buttons serve as up down navigation Arrow characters indi cate right side button context If additional menus are available the arrow character will be shown Main Menu Screens Note After successful pass word entry all screens with edit able parameters will have read write capability Without pass word entry these screens will be read only Utility Menu Screens Password Log ...

Page 18: ... Client Server selection keep both Client and Server selected This will be appropriate for general use 8 When prompted Select Installation Folder specify the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Select the appropriate Everyone or Just Me box and conti...

Page 19: ...nnections verify IP addresses are set correctly ver ify Subnet masks are set correctly and verify AC power is properly applied to the BASIS 19 Click on the BASIS 902zz in the inventory root A view of applicable device tabs will open Click the DSP tab and the current DSP configuration of the BASIS will be displayed 20 Right click on the Design Editor icon in the lower left of your display select Ne...

Page 20: ... used will be copies of other channels CobraNet Channel Resolution All CobraNet audio will be processed internally within BASIS 902zz at 24 bit resolution The BASIS 902zz may receive any valid resolu tion off of the network This is currently 16 bit 20 bit and 24 bit Audio via inbound bundles may be in any combination of these resolu tions and the BASIS will process the data accordingly All DACs wi...

Page 21: ...municate with the BASIS 902zz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port input output I O This I O port is used for accessing Ethernet IP settings stand alone control capabilities system health data firmware version information and other related data Should any system pr...

Page 22: ...lick OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the letter h for help and then press the Enter key This will prompt the BASIS 902zz to post its menu text The h key is the Help prompt for the BASIS 902zz A text menu will appear This is sent by the BASIS 902zz ...

Page 23: ... opening a Telnet session 1 To open the Telnet session Click Start select Run type Telnet followed by a space then the IP address of the BASIS 902zz you want to communicate with in the text box and click OK 2 If the address entered was correct and network communications with the BASIS 902zz are successful the Telnet session should open 3 Now you have the same options that are available in the Seri...

Page 24: ...output 6 313 milliseconds 3 646 milliseconds Program Outputs 8 Connector Type 4 HD 15 dataport connections Cable Type QSC DataPort cable QSC p n DPC x x designates cable length in feet Available stock Lengths 1 2 3 4 5 6 10 and 20 ft custom lengths available Maximum Qualified Length 32 8 ft 10 m Control Room Foldback Monitoring Connector Type 5 pin Phoenix Style a k a Euro Style detachable termina...

Page 25: ...uts 6 discrete inputs for TTL logic voltage control or passive resistive Connector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single ended ground referenced Pinout 1 Signal 2 CHASSIS GND Normal Operating Range Reads signals between 0 5V nominally Potentiometer Operation Use 10K for full range Voltage Tolerance 48V Current Output 0 5mA with 10K pot for passiv...

Page 26: ... suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with your networking systems No agent employee or representative of QSC has any authority to alter or modify in any manner the disclosures and recommendations set forth herein QSC Audio Products 3 Year Li...

Reviews: