This section outlines one of the simpler methods of getting familiar with your BASIS and the QSControl.net software. The goal of this 
procedure is to get your computer and the BASIS connected and communicating and the QSControl.net software installed and running. 
After the software is installed and running, refer to the software’s Help file for all software related operation/issues. Note! The default 
password for the BASIS is “qsc” (no quotes, lower case).

1-

 Turn off the computer and unplug the power cord from the BASIS 722az.

2-

 Connect a CAT-5 crossover cable from the computer’s network interface card (NIC) to the BASIS QSControl jack (example 1, page 6).

3-

 Reconnect the power cord to the BASIS 722az (turn it on). Using the BASIS LCD display and controls, navigate the menu to the IP 

Address and make a note of it. In steps 12 and on, you will need to change the IP address of the BASIS or your PC. 

4-

 Turn on the PC and start Windows. You must have Administrator rights and be signed on as Administrator in order to install the 

QSControl program. Ensure you are signed on to the computer as the Administrator.

5-

 Place the QSControl.net CD-ROM in your CD-ROM drive. The install wizard should start. If not, you can also select 

Start 

then 

Run

 

and browse for the file named 

setup.exe

 from the CD.

6-

 The installer queries the computer for available drive space and other information. If required MDAC library (Microsoft) files are not 

already on the computer, the library files are installed. You must accept the Microsoft software agreement in order to install the MDAC 
library. It may be necessary to reboot the computer after library installation.

7-

 At the prompt for “Client/Server” selection, keep both Client and Server selected. This will be appropriate for general use.

8- 

When prompted “Select Installation Folder”, specify the installation directory or accept the default location. 

9-

 You will be prompted to select an installation accessible by everyone (non-secure) or an installation accessible only to you (secure). 

Select the appropriate Everyone or Just Me box and continue. Installation proceeds.

10-

 Reboot only if your computer prompts you to do so.

11-

 Right click on the 

My Network Places

 icon on your computer’s desktop. Select 

Properties

. Select 

Local Area Connection

, and 

view its properties (click 

Properties

 tab). Highlight the 

Internet Protocol Properties

 tab and view its properties. You will see an 

entry field for the IP address. Decide whether you want to change the IP address of your computer to be similar that of to the BASIS 
(easiest if you have many BASIS units) or if you want to change the IP address of your BASIS to be similar to that of the computer. This 
is a network management decision.

12- 

Change the IP address of the BASIS (or computer) to be compatible with that of the computer (or BASIS). Typically, this is done by 

making the IP address of one of the devices 1 digit different in the last octet (group of digits in IP address). If changing the computer’s 
settings, write down the current values, in case you want to revert later.

13-

 The subnet mask address should be exactly the same for both the computer and the BASIS. The Gateway address should not be 

altered as it is not used.

14-

 After you are satisfied with all your settings, close all open windows and start the QSControl.net program. Select

 Start

Run,

 

QSControl.net

QSControl.net.exe

.

15-

 The login screen should open. The default password is “qsc” (lower case, no quotation marks). Select “Logon to Local Computer” 

and click OK.

16-

The QSControl.net Venue Manager window will open.

Summary of Contents for BASIS 722az

Page 1: ...TD 000145 00 rev A TD 000145 00 BASIS 722az 8x8 Control and Monitoring Signal Processor Hardware Manual...

Page 2: ...cord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE...

Page 3: ...tablets etc all at the same time from anywhere a connection to the QSControl network is available The QSControl network can also be managed from a single computer running both the client and the serv...

Page 4: ...g so will ensure a network with predictable behavior and one that offers the highest level of confidence and long term reliability Second the BASIS 722az and QSControl net system are targeted at netwo...

Page 5: ...monitor your BASIS 722az BASIS 722az QSControl Port NIC CAT 5 Crossover Cable QSControl net Example 2 Unmanaged Switch This example illustrates an unmanaged Ethernet network An unmanaged switch is use...

Page 6: ...affic The partitioning provides a dedicated virtual local area network VLAN for the BASIS 722az and all other QSControl devices including a management PC running the QSControl net server or client app...

Page 7: ...or out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack M...

Page 8: ...Windows 2 If there are any programs running please close them now Be sure to leave Windows running 3 Place the QSControl net CD ROM in your CD ROM drive If your system supports the Auto Run feature i...

Page 9: ...on off or state change events the variable resistor input provides full 8 bit resolution allowing for incremental change events Refer to the illustrations for connection recommendations NOTE 48 volts...

Page 10: ...io and amplifier status monitoring This can be four 2 channel amplifiers or one 8 chan nel amplifier or other suitable combinations If connecting a multi DataPort amplifier ensure all the DataPorts of...

Page 11: ...her side of the display are used to navigate through the menus The rotary select accept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accep...

Page 12: ...lt Boot Screen Right side buttons serve as up down navigation Arrow characters indi cate right side button context If additional menus are available the arrow character will be shown Main Menu Screens...

Page 13: ...Client Server selection keep both Client and Server selected This will be appropriate for general use 8 When prompted Select Installation Folder specify the installation directory or accept the defaul...

Page 14: ...nections verify IP addresses are set correctly ver ify Subnet masks are set correctly and verify AC power is properly applied to the BASIS 19 Click on the BASIS 722az in the inventory root A view of a...

Page 15: ...imited TCP IP communications with the BASIS 722az Once communication has been re estab lished the file transfer can be tried again or the old application file used until the source of the data transfe...

Page 16: ...ick OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the letter h...

Page 17: ...opening a Telnet session 1 To open the Telnet session Click Start select Run type Telnet followed by a space then the IP address of the BASIS 722az you want to communicate with in the text box and cli...

Page 18: ...4dB 20Hz 20KHz typ 60dB Input Sensitivities Vrms 1 5 3 9 18 dBU 5 7 11 8 21 3 27 3 dBV 3 5 9 5 19 1 25 1 Audio Converters 24 bit 48KHz in and out Mute infinite attenuation Delay Analog input through f...

Page 19: ...nical Relay Pinout 1 NC 2 NO 3 COM Switching Capacity nom 1A 30VDC Logic Outputs 4 discrete outputs Connector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single...

Page 20: ...suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with...

Reviews: