IMPORTANT SAFETY INSTRUCTIONS 

 
The symbols below are internationally accepted symbols that warn of potential hazards with electrical products. 

 
This symbol, wherever it appears, alerts you to the presence of un-insulated dangerous voltage inside the enclosure -- voltage 

that may be sufficient to constitute a risk of shock. 
 

This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the accompanying literature. 
Please read the manual. 

 

1.

 

Read these instructions. 

2.

 

Keep these instructions. 

3.

 

Heed all warnings. 

4.

 

Follow all instructions. 

5.

 

Do not use this apparatus near water. 

6.

 

Clean only with a dry cloth. 

7.

 

Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 

8.

 

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce 
heat. 

9.

 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the 
other. A grounding type plug has two blades and third grounding prong. The wider blade or the third prong is provided for your 

safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

10.

 

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they 

exit from the apparatus. 

11.

 

Only use attachments/accessories specified by Attero Tech 

12.

 

Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. 

13.

 

Unplug this apparatus during lightning storms or when unused for long periods of time. 

14.

 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as 
power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been 

exposed to rain or moisture, does not operate normally, or has been dropped. 

15.

 

When permanently connected, on all-pole mains switch with a contact separation of at least 3mm in each pole shall be incorporated 
in the electrical installation of the building. 

16.

 

If rack mounting, provide adequate ventilation. Equipment may be located above or below this apparatus but some equipment (like 
large power amplifiers) may cause an unacceptable amount of hum or may generate too much heat and degrade the performance 

of this apparatus. 

 

  TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. 

 

Summary of Contents for ATTEROTECH Axiom AXP20

Page 1: ...rights reserved QSC and the QSC logo are registered trademarks of QSC LLC in the U S Patent and Trademark office and other countries All other trademarks are the property of their respective owners P...

Page 2: ...ty If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs conv...

Page 3: ...These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio f...

Page 4: ...etooth Pairing Connect Modes 3 4 3 1 1 Manual Mode 3 4 3 1 2 Reconnect Mode 3 4 3 1 3 Exclusive Mode 3 Bluetooth Audio Bridging 4 4 3 2 1 Media Bridging only 4 4 3 2 2 Call Bridging only 4 4 3 2 3 Cal...

Page 5: ...Attero Tech by QSC Axiom Product Family User Manual QSC LLC 2020 614 00063 Device Specifications iii ML1 Specs iii USB1 Specs iii BT1 Specs iv AXP2O Specs iv AXPio Specs v...

Page 6: ...th The Axiom bus also supports daisy chain connectivity of up to two Axiom devices to provide flexible modularity for various audio device connectivity in installed AV systems 8P8C Pin TIA 568A Pair C...

Page 7: ...nt education and hospitality venues ML1 What s in the Box The ML1 comes supplied with the following o Axiom ML1device o Includes interchangeable white and black Decora style inserts o 1 White US Singl...

Page 8: ...ox taking care to not trap the cabling Once in place secure it with the screws provided Once the unit is secured in the wall box fit the Decora plate and secure it with the screws provided Now you may...

Page 9: ...rs to 20 dBu ML1 Controls The ML1 controls the desired input gain simply using the coinciding input knob see Figure 4 Turning the knob clockwise raises the level while counter clockwise lowers ML1 Dev...

Page 10: ...ce support allowing users to connect their laptops to integrate the room s audio into their web conferencing application Microsoft Teams Zoom etc USB1 What s in the Box The USB1 comes supplied with th...

Page 11: ...wall box taking care to not trap the cabling Once in place secure it with the screws provided Once the unit is secured in the wall box fit the Decora plate and secure it with the screws provided Now y...

Page 12: ...erface will declare itself o 1x1 Speakerphone no host AEC o 1x1 Speakerphone host AEC o 2x0 1x0 Line in Line out USB audio will be routed through the following Axiom ports based on each corresponding...

Page 13: ...layback or Bluetooth conference call bridging BT1 What s in the Box The BT1 comes supplied with the following o Axiom BT1 device o Includes interchangeable white and black Decora style inserts o 1 Whi...

Page 14: ...all box taking care to not trap the cabling Once in place secure it with the screws provided Once the unit is secured in the wall box fit the Decora plate and secure it with the screws provided Now yo...

Page 15: ...name visible to other devices is BT1 xx xx xx This name can be customized by the installer using the unIFY Control Panel software If a successful pairing is made during the pairing period the status L...

Page 16: ...es to a networked audio based conferencing system The addition of Bluetooth connectivity provides simple bridging of far end meeting participants for on the fly meeting productivity and backup confere...

Page 17: ...vel analog outputs for connectivity to mixers amplifiers and signal processors o Axiom port Supports connectivity to any Attero Tech Axiom endpoint o RS 232 Provides RS 232 connectivity to control sys...

Page 18: ...he DC power input on the AXP2O The power LED on the AXP2O should illuminate green Additionally the Axiom wall plate should also start up and become ready to operate With the cable attached carefully p...

Page 19: ...ed Input Wiring Guide TRS Plug GND Sleeve Tip Ring Output 2 Output 1 GND 2 Wire Cable Shield 2 Wire Cable Shield RCA R GND Tip RCA L Tip Output 2 Output 1 GND Sleeve Sleeve Figure 20 AXP2O to Unbalanc...

Page 20: ...for connectivity to mixers amplifiers and signal processors o Axiom port Supports connectivity to any Attero Tech Axiom endpoint o RS 232 Provides RS 232 connectivity to control systems for extending...

Page 21: ...nput on the AXPio The power LED on the AXPio should illuminate green Additionally the Axiom wall plate should also start up and become ready to operate With the cable attached carefully place the Axio...

Page 22: ...e 24 I O ports wiring Balanced to Balanced Wiring 3 Wire Cable Pin 1 Pin 2 GND Balanced Terminal Block Plug Pin 3 1 2 3 XLR M 3 Wire Cable Sleeve Tip GND Ring 1 2 3 TRS Plug Balanced Terminal Block Pl...

Page 23: ...of 0 dBu to 24 dBu Output Settings The output gains are adjusted using 2 rotary pots A small screwdriver is needed to adjust the gain levels The outputs have an adjustable gain range of 0 to 24dB allo...

Page 24: ...Attero Tech by QSC Axiom Product Family User Manual QSC LLC 2020 614 00063...

Page 25: ...e selector switches for audio channel routing on the top of the unit The unit shall have a USB mini type B connector for software configuration of the unit There shall a single bi color status LED on...

Page 26: ...wo installer selectable analog inputs or outputs The line level analog inputs shall have an attenuation range of 24 to 0 dBu allowing an input full scale input signal range of 0 dBu to 24 dBu The line...

Page 27: ...ce 2kOhms at any gain mic 10kOhms Line Maximum Input Levels 20 dBu minimum gain XLR 18 dBu minimum gain 1 4 THD N 0 05 1 kHz 3 dBFS input 20 20kHz Frequency Response 20 20 kHz 1 dB 1 4 50 20kHz 1 dB X...

Page 28: ...perating Temperature 0 to 40 C Audio Inputs Bluetooth Line Input Types Stero Bluetooth v3 0 audio receiver Stereo Unbalanced Inputs on 3 5mm TRRS Bluetooth Range 10m 30ft minimum Input Impedance 10k O...

Page 29: ...EACH Environmental Operating Specifications Operating Temperature 0 to 40 C Audio Inputs when selected I O Type Two switchable Balanced and RF filtered 3 pin de pluggable terminal blocks Maximum Input...