![QRPproject DL-QRP-AG Manual Download Page 27](http://html1.mh-extra.com/html/qrpproject/dl-qrp-ag/dl-qrp-ag_manual_767294027.webp)
Version: 13. September 2004
27
careful not to put it in at a wrong angle. Solder the coil i place and put on
the covering core. The can should be mounted loosely, not yet soldered.
[ ] L1
Neosid filter 7.1 F2
C/D7
(17 turns primary / 8 turns secondary)
Now we will continue with the Band modules slots.
The connector strips should be carefully mounted at a right angle to the pc
board. Good practice is to start soldering on lead at the middle of the strip,
an check and adjust for proper position, before soldering the rest.
[ ] Connector strip 5A
E7
[ ] Connector strip 5B
E5
[ ] Connector strip 4A
E7
[ ] Connector strip 4B
E5
[ ] Connector strip 3A
F7
[ ] Connector strip 3B
F5
[ ] Connector strip 2A
G7
[ ] Connector strip 2B
G5
[ ] Connector strip 1A
H7
[ ] Connector strip 1B
H5
Now the corresponding pins for the band switching:
[ ] pin 5
E7
[ ] pin 4
E7
[ ] pin 3
F7
[ ] pin 2
G7
[ ] pin 1
H7
Now for the only fixed bridge on the pc board. This should be made from
isolated wire in square E4/E5, and soldered in.
This section cannot be tested yet, as the band set oscillator and the VCO of
the band modules are needed. Put the main pc board aside, and finish one
band module. We recommend the 40 meter module.
If the bandmodule PCB still has pieces of PCB material left and right, cut of
this parts by breaking them along the lines.
Band module 40 Meter
[ ] P1
250R
Piher PT6 lying
[ ] C1
220pF
[ ] C2
150pF
[ ] C3
left out
[ ] C5
22nF
223
[ ] C6
10nF
103
[ ] C7
22nF
223
[ ] C8
22nF
223
[ ] C9
47pF
473
[ ] C10
220pF
n22 or 221
[ ] C12
10nF
103
[ ] C15
10nF
103
[ ] C16
10pF
10p
[ ] C17
10pF
10p
[ ] C18
22nF
223
[ ] C19
22nF
223
[ ] C20
27pF
27p
[ ] C21
10nF
103
[ ] R1
68K
[ ] R2
27K
[ ] R3
1K
[ ] R4
10R
[ ] R5
56K
[ ] R6
68R
The next resistor has to be adjusted. Criteria is the oscillation of the VCO.
R7 should be as small as possible but if it is to small, the VCO oscillation
will become instable. Start with an 1k in this position. If the VCO does not
start oscillation durin test, try 2k7 or 3k3. Both values are added to the
kit´s bandmodule pack.
[ ] R7
1K or 2k7 or 3k3, see text
[ ] R8
150K
[ ] R9
100K
[ ] R10