background image

 

Before installation on the wall, please check below size carefully and choose the correct expansion bolt and screw. 
 

Product installation & connection steps:   

1)

 

Please open the packing carton to verify that products good, and unplug the power cord to ensure the output terminal 

without any connection;   
2)

 

Please connect the battery in right way, and check the voltage & polarity of positive/negative carefully;   

3)

 

Connect the solar panels properly, and check    the voltage & polarity of positive & negative carefully;   

4)

 

Select the machine priority mode: for solar energy systems , select the PV priority, otherwise AC priority   

5)

 

Press the ON/OFF button to start, to ensure it can work normally and connect the mains.   

6)

 

Open the solar input switch for solar charging;   

7)

 

Connect the input terminals with the loads which are turn off, and then open them one by one. 

 

2.2 Precautions   

1) connect properly to the battery and solar panel, reversed or high voltage will cause serious damage.   
2) be connected to ground securely   
3) don’t load beyond the rated power. If connect the refrigerators, fans such inductive loads, the loading capacity should 
not exceed the 30% of the rated power.   
4) don’t install this products outdoors, avoid the electricity leakage caused by any water.   
5) when the product work properly, the cabinet will have a certain degree of heat. It should be installed at a distance over 
50 cm far away the human venue area. To ensure adequate ventilation around ,and away from flammable materials   
6) If the product malfunctions, disconnect the mains input immediately , and then shut down. Disconnect the battery and 
solar  panel  switch,  and  take  note  of  the  failure  and  fault  phenomena,  etc,  contact  your  dealer  promptly,  and  give  the 
products to the professional personnel.   

 

3. Working principle   

3.1 System circuit diagram

 

 

 

 

 

 

Inverter 

AC 

Load 

Battery 

Solar panel   

Solar controller 

AVR 

Inverter/charger 

Isolation 
Transformer 

Filter 

Input 

Summary of Contents for Monolith 53890

Page 1: ...USER MANUAL Pure Sine Wave Solar Inverter MODEL 53890 53891 53892 www qoltec com...

Page 2: ...lar charging technology more efficient 1 5 With wide frequency range auto tracking for main frequency and inverter output 50 60Hz 1 6 Intelligent selection between main mode and solar mode more energy...

Page 3: ...Connection diagram 500VA to 2 5KVA Connection diagram 3KVA to 5KVA Battery Loading Solar inverter Main socket Solar panel Battery Solar panel Main socket Loading...

Page 4: ...tions 1 connect properly to the battery and solar panel reversed or high voltage will cause serious damage 2 be connected to ground securely 3 don t load beyond the rated power If connect the refriger...

Page 5: ...e system will convert the energy of battery and PV systems and give power supply to the user equipment 2 Solar energy No strong enough Priority mode AC priority AC power input Normal AC input will pro...

Page 6: ...r equipment During the evening or rainy days with no sun the system will convert the energy of battery and give power supply to the user equipment Inverter AC Input AVR Isolation Transformer Filter Lo...

Page 7: ...nly through MPPT control system 5 Solar energy No strong enough Priority mode PV priority AC power input Wrong The system will convert the energy of battery and PV systems and give power supply to the...

Page 8: ...ime solar energy can charge the battery normally 4 Product panel and display details Isolation Transformer Isolation Transformer Load Load AVR AVR Inverter charger Inverter charger Input Input AC AC B...

Page 9: ...attery Voltage indication When lighting here shows solar panel voltage lighting Here shows city power input voltage lighting here shows output voltage Current indication When lighting here shows solar...

Page 10: ...Long light means normal Light off or flash means connect unusual Middle Yellow LED Battery connect state long light means normal light off or flash means connect unusual Right Red Led means abnormal...

Page 11: ...s inverter will output normally and connect the loading then start the loads one by one 5 4 Turning off steps 1 Turn off the loads one by one 2 Press the shut down Off manually in 3 seconds and cut th...

Page 12: ...sfer time 4Ms typical value Max 6 Ms Efficiency Inverter mode 80 Inverter overload 110 130 shutdown at 30s 130 150 shutdown at 3s Short circuit Systems automatically shut down Alarm Mains abnormal 1ti...