QOLSYS IQ GLASS-S Installation Manual Download Page 2

Document#: IQGS-IM-02-18 
Revision#: 2/14/18 
Issue Date: FEB 2018 
Qolsys Product #: QS1431-840

[email protected]

CONTACT TECH SUPPORT

GOT QUESTIONS?

Qolsys Inc. proprietary.   

Reproduction without permission is not permitted.

FCC ID: 2ABBZ-RF-ARGB

IC: 11817A-RFARGB

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired 

operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and

(2) this device must accept any interference, including interference that may cause undesired operation of the device.

Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et

(2) cet appareil doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.

TESTING 
MODE

STEP 

7a

FG-701 
Glassbreak Simulator

Test Mode:

 

Place the sensor in test mode by disconnecting the batteries for 30 seconds then 
reconnecting. Test mode is active for 5 minutes upon the sensor powering on. The LED blinks 
every second when the sensor is in test mode. The IQ Glass-S does not transmit an RF Signal 
while it is in Test Mode. Please refer to the table on the right for the LED indicator guide. The 
sensor will exit test mode after the first 5 minutes of power up.

CONDITION

RED LED

Initial Power Up

Test Mode

Test Mode, alarm event

Normal Mode, alarm event

Low Battery

Flash rapidly for 5 minutes

Flash once per second

Rapid flash for 2 seconds

SOLID for 5 seconds

Flash once every 30 seconds

LED Indicator Guide:

Sensitivity

Two dip switches allow you to customize the sensitivity and 
detection range of the IQ Glass S. The factory default is set to 
MAX. Please refer to the table below to customize the sensitivity. 

ON

1

2

SENSITIVITY

DETECTION RANGE

MAX

MEDIUM

LOW

LOWEST

20ft

1

2

13ft

8ft

5ft

OFF

ON

OFF

OFF

OFF

ON

ON

ON

Switches

Set dip switches based on desired detection range. 

ACTIVATE

TEST

FLEX

MAN

Red Start

Button

Set the FG-701 switches to the TEST and MANual 
modes.

Position the FG-701 near the protected glass and point 
the speaker directly at the glass break detector. 

IMPORTANT

: If window coverings are present, close 

them fully and hold the FG-701 

behind

 the window 

coverings for testing.

Press the red start button and the FG-701 will generate 
a burst of glass break audio. 

If the LED on the IQ Glass-S sensor flashes rapidly for 
2 seconds an alarm event has been detected and the 
range is acceptable for audio. If the LED does not flash, 
position the IQ Glass-S closer to the glass and try 
again. 

Note:  The IQ Glass-S does not transmit an RF Signal 
while it is in Test Mode.

1.

2.

3.

To properly test the IQ Glass-S sensor, the 
FG-701 Glassbreak Simulator is required.  

STEP 

7b

STEP 

7c

TESTING 
MODE

TESTING 
MODE

SECURE

CONNECTS

USING

319.5 MHz

Equipment

BP21056