Qnubu PREN0052 User Manual Download Page 6

ENGLISH

CONFIGURATION 

QNUBU

TEMPERATURE & TIME SETTING:

Increase

button

Set button

Decrease 

button

Countdown

button

TIME

TEMPERATURE

PANTALLA INICIAL

CONF. TEMP.

CONF. TIEMPO

-Countdown: 

 After closing the plates, press the countdown start 

button.

-Temperature setting:

Press the SET button            1 time, the display shows “SP”, then use the 

buttons                    to increase or decrease.

-Time settings:

Press the SET button            1 time, the display shows “ST”, then use the 
buttons                    to increase or decrease the pressing time.

-Confirm settings:

 

After finishing setting the time and temperature you 

must press SET          again to confirm settings.
The plates will start to heat up

DO NOT FORCE THE PRESS!

IF YOU TRY TO APPLY MORE PRESSURE 
MAY DAMAGE THE PRODUCT.

PRESSURE RELEASE VALVE ADJUSTMENT: 

Before applying 

pressure with the hydraulic jack CLOSE the pressure release

 

valve turning to the RIGHT. Then 

the system will be ready to apply pressure.

IMPORTANT: 

Apply the pressure smoothly once the pressure limit is reached, do not force the 

machine. May cause oil leaks and hydraulic system failure NOT covered by warranty.
To realease pressure on the plates, OPEN the pressure release valve by turning it to the LEFT. 
The hydraulic system will release the pressure and the plates will open automatically.

CLOSE

OPEN

Reviews: