Installation and wiring
The distance between
two mounting bracket,s;;soomm
/////////
�36mm
�10mm
Single track installation
Two piece single track installation
( Double curtain)
1.Please check and keep the
lock bar at the left side as
the image
IM::HH::HHM
1.Pull the lock bar and make
it slide out of the limit hole
uoc::>
2.lnsert the motor to main box 3.Slide the lock bar and make sure
2.Slide to the left
Motor A
it is in the limit hole on the right
A
Caution
• Please follow the installation drawing above
• Make sure the lock bar in the correct position as image
• Ceiling must be stong enough to hold the track, motor
and curtain
S.S.mo.,,, moro,
�
��
Af
t
�
Antenna
------------=
�
,-
---,
Program button
----
�
M'
-------
A
Caution: external manual switch is dry contact mode, function
of both ports keep the same.
Port 1
--------
b-
-
-.-
-
+
-
-r'
'-
Port 2
----------,
LED indicator
AC 100V-240V
Application 1:
Blue=Neutral
�--....
1,
A
;,;
C
;,;
1
;;
00
;,;
V
;,;
-
,;;,
24
;,;
0V
�
.
:;;:
,::
�
::::'
Brown=Live
+
Yellow/Green=Earth
Dry contact_ RS485 control, Radio control
Available for
more motors
Motors
Available for
RS485 control
Manual control line can be 30M
Application 2:
Blue=Neutral
1,
A
:;:C
a.
2:a3�0V-50=60::,H
::;
z
�
�
s::,
:�:�;�g���;�
p
Yellow/Green=Earth
AC power control
PC control
Application 3:
AC 100-240V
Impulse manual switch
Red=Live
Blue=Neutral
Black=Up/Down
Brown=Down/Up
Yellow/Green=Earth
AC power control, Dry contact, RS485 control, Radio control
Automatical
remenber journey
Motor stop at the open and close ends during the first operation,and keep it as the stop journey even the power off and on again
Over current protection
Able to effectively avoide electric parts burnt or damage with over loading, and its coming fire damage. If there are two times
short circuit caused by over loading in 1 min, the red indicator light, the motor enter into proection mode. It has to be re power
to start again
Page3
Operation instructions
Please select channel for multi-channel transmitter before operation
0.5s is needed for up/down converting, max single running time is 4 min
I. Programming
� Changing direction
In the case of the motor
goes in wrong direction
Red light flash
slowly, please
do the next step
within 10s
Blue light
flash 3 times
Programmed
Red light flash
slowly, please
do the next
step within 1 Os
Press the PROG button 1 s
Press UP of transmitter
Press STOP on programmed
transmitter and hold for 5s
3 Mid-limit position setting
---- Set
Blue light
flash 3 times
Only one can be set
C.
m
"C
0
�
o·
0
"C
CD
Move to
----mid-limit position
Blue light
flash 3 limes
Release and
press stop again
Changed
---- Deleted
1 Blue light
flash 3 times
Press UP+ DOWN for 1s
Press STOP and hold for 2s
Press UP+ DOWN and hold for 5s
4 New transmitter adding
0
::,
Red light flash slowly, please
do the next step within 10s
Blue light flash 3 times
Press STOP on programmed
transmitter and hold for 5s
Press UP of new transmitter
Added
& Single code deleting
If you are using multiple chamel transmitter please select the channel first
Red light flash slowly, please
do the next step within 10s
Press STOP on programmed
transmitter and hold for 5s
Press DOWN
Deleted
Blue light flash 3 times
8 All code deleting
Journey will be deleted and the running direction will be the factory defaulted mode, keeping the touch function
CD
0
C.
Red light flash
slowly, please
do the next step
within 10s
Deleted
Indicator die out
Press STOP on programmed
transmitter and hold for 5s
Press PROG button
on back side and hold 7s
7 Manual function setting
Press the PROG
button on motor
and hold for above 7s
Red light flashes
slowly in 3s
Setted
Red light flash Blue light flash
qiuck in next 3s 3 times after 7s
Page 4
Press the PROG button
on motor and hold for 3s
Press the PROG
button again
Manual function demonstration
Deleted
P/N:4.01.0385
Features
• AC100-240V, widen voltage input for different voltage power area
• Light touch to start the motor by softly drag the curtain fabric, it will open or close the
curtain automatically
• When the electricity off, it can be manually operated
• You can set the third limits in the middle between the open and close ends
• Soft start and soft stop, quiet and smooth running
• II takes the first open and close position as its stops, and preserves gap
between pulleys and gears to avoid parts clashing.
• Various control way for application requirements
•
Flexible quiet design:
high-precision drive, leading intelligent design, beside, slow open and close make it light and smooth moving.
•
Various control:
According to the application, with option of RF control, hard wire, RS485 bus line control etc.
•
Remenber limits:
Motor remembers the first open and close stops even after power cuts.
Parameters
Model number
Rated torque
Speed
Housing size
Rated voltage
Rated power
IP level
AM68-1/80-EM-GP
AM68-2/80-EM-GP
Loading diagram
....\
io
CJ<-
�
<$)6
r.
.
�
/o't-.s,.
�
�1 ... '""
l
lN.m
2N.m
l
Track length
Single motor with Single motor with
double pulley
single pulley
4m
90kg
75kg
8m
82.5kg
67.5kg
12m
75kg
60kg
Structure and accessories
Master box
Lock
Curtain motor
14cm/s
14cm/s
�
310x68x50mm
310x68x50mm
�
AC100-240V 50/60Hz
AC100-240V 50/60Hz
�
�
65W
80W
�
IP20
IP20
0®
Single motor with Single motor with Single motor with Single motor with Single motor with Single motor with
double pulley
single pulley
double pulley
single pulley
double pulley
single pulley
67.5kg
60kg
52.5kg
60kg
52.5kg
45kg
52.5kg
45kg
37.5kg
45kg
37.5kg
30kg
46.5kg
31.5kg
31.5kg
24kg
>< ><
Belt
Lock
Hook
Pulley
@
[
'"
�
l
�-----_::==:::--:::====-
�-----� '------
[
�
][
/
][
I
][
�
Splice
Connector
Single track bracket
Double track bracket
�
�
�
-)
Page 1
Solution
-
-
--
--
�
Power input
0
Single motor with single pulley
--
Pow
�
�
I
�
Power input
@ Double tracks with double pulleys
Power input
Pow9
Pow
::1
1
J
fr
�
.. :,..;-
[
b'
1
::
.. :;,""
rG,i:t.. .. ,
--
�
@ Single motor with double pulleys
Power input
Powe
�
�
I
�
8
Double tracks with single pulley
Power input
@ Double motors with double pulleys
Pow
7einput
-
r
l�pulse switch
iu
Power input
Pow
=:1
1
Pow::J
l
.
�tf'"
sw,m;-
�
l
b
j
�
..,.,.
-
c
-
:-
--=
-
""'"-
.-:
==i
01
General switch control
© Impulse switch(dry contact) single control and group control solution
Power input
Power input
Power input
Power input
:... J
r
Computer Control
:... J
r
:... J
l
PC control
@ PC control-single control and group control solution(compatible with above solution©)
Power input
Power input
Power input
Power input
r
r
r
,
�
�-
r.:.
-
J
G)
RF control- single control and group control solution
Page 2