2 – Installation
Planning the Installation
2-2
D000024-000 Rev. A
Q
2.1.1
Cable Requirements
2.1.1.1
Cable Distances
When planning the location of the switches, consider the distance limitations for
signaling, EMI, and connector compatibility. It is recommended that the user does
not exceed specified transmission rate and distance limits.
NOTE:
Building and electrical codes vary depending on the location. Comply with
all code specifications when planning the site and installing cable.
When running cable to the equipment, consider the following:
❥
Do not run cables where they can be stepped on or rolled over.
❥
Be sure cables are intact with no cuts, bends, or nicks.
❥
If the user is making a cable, ensure that the cable is properly crimped.
❥
Provide proper strain relief for standard IB cables.
❥
Support cable using a cable manager mounted above connectors to avoid
unnecessary weight on the cable bundles.
❥
Bundle cable using velcro straps to avoid injuring cables.
❥
Keep all ports and connectors free of dust.
❥
Untwisted Pair (UTP) cables can build up Electrostatic Discharge (ESD) charges
when being pulled into a new installation. Before installing category 5 UTP
cables, discharge ESD from the cable by plugging it into a port on a system that
is not powered on.
❥
When required for safety and fire rating requirements, plenum-rated cable can
be used. Check the local building codes to determine when it is appropriate to
use plenum-rated cable, or refer to IEC standard 850.
2.1.1.2
Uninterruptible Power Supply
Consider the following when selecting Uninterruptible Power Supply (UPS)
equipment:
❥
The minimum amperage requirements for a UPS:
❥
Calculate VA (Volt-Amps): Locate the voltage and amperage requirements
for each piece of equipment (usually located on a sticker on the back or bottom
of the equipment). Multiply the numbers together to get VA.
Summary of Contents for SilverStorm 9000
Page 1: ...D000024 000 Rev A Page i Q S i m p l i f y SilverStorm 9000 Hardware Installation Guide...
Page 2: ...SilverStorm 9000 Hardware Installation Guide Q Page ii D000024 000 Rev A...
Page 10: ...1 Introduction Technical Support 1 4 D000024 000 Rev A Q...
Page 38: ...2 Installation Installation Tasks 2 28 D000024 000 Rev A Q...
Page 50: ...Regulatory Compliance Information B 6 D000024 000 Rev A Q...