4–Diagnostics/Troubleshooting
Power-On Self Test Diagnostics
59265-02 B
4-7
Logged-In LED Indications
Port diagnostics are indicated by the Logged-In LED for SFP and XPAK ports as
shown in
Figure 4-6. Logged-In LED
The Logged-In LED has three indications:
Continuous illumination: A device is logged in to the port.
Flashing once per second: A device is logging in to the port, or the port is in
the diagnostics state.
Flashing twice per second: The port is down, offline, or an error has
occurred.
If a Logged-In LED is flashing twice per second, review the event browser for
alarm messages regarding the affected port. You can also inspect the alarm log
using the Show Alarm command. If there is an error, alarm messages may point to
one or more of the following conditions:
XPAK Port
Logged-In LED
SFP Port
Logged-In LED