3–Fibre Channel Configuration
Using Fast!UTIL for Custom Configuration
36
BK3254601-00 C
shows the options you can use to customize the Dell update package
installation behavior.
Figure 3-6. Command Line Options
Using
Fast!
UTIL for Custom Configuration
This section provides detailed configuration information for advanced users who
want to customize the configuration of the adapters and connected devices using
Fast!
UTIL (the QLogic Fibre Channel Adapter BIOS utility) in a pre-OS
environment.
To configure adapters using
Fast!
UTIL:
1.
During the Host Bus Adapter BIOS initialization, press ALT+Q or CTRL+Q. It
may take a few seconds for the
Fast!
UTIL menu to appear.
2.
When the Select Host Adapter window appears, select the adapter type.
3.
In the Adapter Settings window (see
),
configure the adapter settings.
4.
A message indicates that the configuration settings have been modified.
Select
Save changes
.