5–Fibre Channel Noninteractive Commands
-l (Display LUN Info)
5-22
SN0054667-00 C
If the read/write buffer test fails, the system shows the following information:
Loop/port ID
(the loop ID of the adapter when operating in loop mode).
Status
:
Success
—The test passed.
Error
—A data miscompare or link status firmware error occurred.
Failed
—A link status error, SCSI write buffer error, or SCSI read buffer
error occurred.
Unknown
—The target was not present.
Unsupported
—The device does not support this test.
Data Miscompare
—The possible values are:
0 (no data miscompares)
Device not present
Get link status failed
Read buffer failed
R/W buffer not supported
Write buffer failed
Link Failure
—Number of link failures
Loss of sync
—Number of sync loss errors
Loss of signal
—Number of signal loss errors
Invalid CRC
—Number of invalid CRCs
-l
(Display LUN Info)
This command shows LUN information for:
All adapters
A specific target
A specific LUN on a specific target
To show the LUN information for
all target
devices for a
specific adapter Instance
,
issue the following command:
#
qaucli -pr fc -l (<
hba instance
> | <
hba wwpn
>)
To show the LUN information for a specific device for a specific adapter port, issue
the following command:
#
qaucli -pr fc -l (<
hba instance
> | <
hba wwpn
>) (<
target port
id
> | <
target wwpn
>)
Summary of Contents for QConvergeConsole CLI 2400 Series
Page 1: ...SN0054667 00 C User s Guide QConvergeConsole CLI 2400 2500 3200 8100 8200 Series...
Page 20: ...xx SN0054667 00 C User s Guide QConvergeConsole CLI 2400 2500 3200 8100 8200 Series...
Page 28: ...1 System Requirements Supported QLogic Adapters 1 4 SN0054667 00 C...
Page 134: ...6 iSCSI Noninteractive Commands vpd Display VPD Information 6 28 SN0054667 00 C...
Page 204: ...9 Fibre Channel Interactive Commands Exit 9 46 SN0054667 00 C...
Page 365: ......