5–Fibre Channel Noninteractive Commands
-kr (Run Read/Write Buffer Test)
5-20
SN0054667-00 C
Run Adapter Diagnostics Read-write Buffer Test
The
{(-ex | exclude) <
target wwpn
>}
parameters specify a device that
will be excluded from the read/write buffer test.
The system shows the following information after a read/write buffer test
completes:
Loop ID/status
Data miscompare
Link failure
Loss of sync
Loss of signal
Invalid CRC
lists the <
param name
>, <
param alias
>, and
<
param value
>
options.
Table 5-6. Diagnostics Parameters
Name
<param name>
Alias
<param
alias>
Value
<param value>
Description
DataPattern
DP
Test pattern in hex for-
mat
a
Customized (00–FF)
Random pattern
CRPAT
b
CJTPAT
c
CSPAT
d
00, 55, 5A, A5, AA, FF (see
)
—
—
Loopback test only
Loopback test only
Loopback test only
DataSize
e
DS
8, 16, 32, 64, 128, 256,
512, 1024, 2048
Actual data transferred dur-
ing any given pass of the
test
TestCount
f
TC
0–65535
0–10,000
Loopback test only
Read/write buffer test only
TestIncrement
g
TI
1–65535
1–10,000
Loopback test only
Read/write buffer test only
OnError
OE
0–2
0 = ignore
1 = stop
2 = loop on error
Summary of Contents for QConvergeConsole CLI 2400 Series
Page 1: ...SN0054667 00 C User s Guide QConvergeConsole CLI 2400 2500 3200 8100 8200 Series...
Page 20: ...xx SN0054667 00 C User s Guide QConvergeConsole CLI 2400 2500 3200 8100 8200 Series...
Page 28: ...1 System Requirements Supported QLogic Adapters 1 4 SN0054667 00 C...
Page 134: ...6 iSCSI Noninteractive Commands vpd Display VPD Information 6 28 SN0054667 00 C...
Page 204: ...9 Fibre Channel Interactive Commands Exit 9 46 SN0054667 00 C...
Page 365: ......