G
–
Commands and Files
Restarting InfiniPath
G-2
IB0054606-02 A
Restarting InfiniPath
When the driver status appears abnormal on any node, you can try restarting (as
a root user). Type:
#
/etc/init.d/openibd restart
These two commands perform the same function as
restart
:
#
/etc/init.d/openibd stop
#
/etc/init.d/openibd start
Also check the
/var/log/messages
file for any abnormal activity.
Summary and Descriptions of Commands
Commands are summarized in
. Names in blue text are linked to a
corresponding section that provides further details. Check the man pages for
more information on the programs.
Table G-1. Useful Programs
Program Name
Function
chkconfig
Checks the configuration state and enables/disables ser-
vices, including drivers. Can be useful for checking homoge-
neity.
Prints out bootup messages. Useful for checking for initializa-
tion problems.
Retrieves path records from the Distributed SA and is some-
what similar to
iba_saquery
. It is intended for testing the
Distributed SA (
qlogic_sa
) and for verifying connectivity
between nodes in the fabric.
Scans the system and reports hardware and firmware infor-
mation about all the HCAs in the system.
Allows management of externally managed switches (includ-
ing 12200, 12200-18, and HP BLc QLogic 4X QDR) without
the IFS software.
Enables packet capture and subsequent dump to file
a
Checks that all hosts in the fabric are up and visible to the
subnet manager and to each other
Checks the status of IB devices when OpenFabrics is
installed
Summary of Contents for OFED+ Host
Page 1: ...IB0054606 02 A OFED Host Software Release 1 5 4 User Guide...
Page 14: ...xiv IB0054606 02 A OFED Host Software Release 1 5 4 User Guide...
Page 22: ...1 Introduction Interoperability 1 4 IB0054606 02 A...
Page 96: ...4 Running MPI on QLogic Adapters Debugging MPI Programs 4 24 IB0054606 02 A...
Page 140: ...6 SHMEM Description and Configuration SHMEM Benchmark Programs 6 32 IB0054606 02 A...
Page 148: ...8 Dispersive Routing 8 4 IB0054606 02 A...
Page 164: ...9 gPXE HTTP Boot Setup 9 16 IB0054606 02 A...
Page 176: ...A Benchmark Programs Benchmark 3 Messaging Rate Microbenchmarks A 12 IB0054606 02 A...
Page 202: ...B SRP Configuration OFED SRP Configuration B 26 IB0054606 02 A Notes...
Page 206: ...C Integration with a Batch Queuing System Clean up PSM Shared Memory Files C 4 IB0054606 02 A...
Page 238: ...E ULP Troubleshooting Troubleshooting SRP Issues E 20 IB0054606 02 A...
Page 242: ...F Write Combining Verify Write Combining is Working F 4 IB0054606 02 A Notes...
Page 280: ...G Commands and Files Summary of Configuration Files G 38 IB0054606 02 A...
Page 283: ......