20–User Diagnostics in DOS
Performing Diagnostics
341
83840-546-00 D
Performing Diagnostics
At the MS-DOS prompt, type
uediag
followed by the command options. The
uediag command options are shown in
. For example, to run all
diagnostic tests on adapter #1 except Group B tests:
C:\>uediag -c 1 -t b
NOTE
You must include
uediag
at the beginning of the command string each time
you type a command.
Table 20-1. uediag Command Options
Command
Options
Description
uediag
Performs all tests on all QLogic 8400/3400 Series adapters in
your system.
uediag -c
<device#>
Specifies the adapter (device#) to test. Similar to -dev (for back-
ward compatibility).
uediag -cof
Allows tests to continue after detecting a failure.
uediag -dev
<device#>
Specifies the adapter (device#) to test.
uediag -F
Forces an upgrade of the image without checking the version.
uediag -fbc
<bc_image>
Specifies the bin file to update the bootcode.
uediag -fbc1
<bc1_image>
Specifies the bin file to update bootcode 1.
uediag -fbc2
<bc2_image>
Specifies the bin file to update bootcode 2.
uediag -fl2b
<l2b_image>
Specifies the bin file for L2B firmware.
uediag -fib
<ib_image>
Specifies the bin file for iSCSI boot.
uediag -fibc
Programs iSCSI configuration block 0. Used only with -fib
<ib_image>.
uediag -fibc2
Programs iSCSI configuration block 1. Used only with -fib
<ib_image>.